Publication: Reliability of distal tibio-fibular syndesmotic instability measurements using weightbearing and non-weightbearing cone-beam CT
dc.contributor.author | Greg M. Osgood | en_US |
dc.contributor.author | Delaram Shakoor | en_US |
dc.contributor.author | Jakrapong Orapin | en_US |
dc.contributor.author | Jianzhong Qin | en_US |
dc.contributor.author | Iman Khodarahmi | en_US |
dc.contributor.author | Gaurav K. Thawait | en_US |
dc.contributor.author | James R. Ficke | en_US |
dc.contributor.author | Lew C. Schon | en_US |
dc.contributor.author | Shadpour Demehri | en_US |
dc.contributor.other | Second Affiliated Hospital of Suzhou University | en_US |
dc.contributor.other | Union Memorial Hospital | en_US |
dc.contributor.other | Faculty of Medicine, Ramathibodi Hospital, Mahidol University | en_US |
dc.contributor.other | The Johns Hopkins School of Medicine | en_US |
dc.date.accessioned | 2019-08-28T06:37:11Z | |
dc.date.available | 2019-08-28T06:37:11Z | |
dc.date.issued | 2018-01-01 | en_US |
dc.description.abstract | © 2018 European Foot and Ankle Society Background: To investigate the reliability and reproducibility of syndesmosis measurements on weightbearing (WB) cone-beam computed tomography (CBCT) images and compare them with measurements obtained using non-weightbearing (NWB) images. Methods: In this IRB-approved, retrospective study of 5 men and 9 women with prior ankle injuries, simultaneous WB and NWB CBCT scans were taken. A set of 21 syndesmosis measurements using WB and NWB images were performed by 3 independent observers. Pearson/Spearman correlation and intra-class correlation (ICC) were used to assess intra- and inter-observer reliability, respectively. Results: We observed substantial to perfect intra-observer reliability (ICC = 0.72–0.99) in 20 measurements. Moderate to perfect agreement (ICC = 0.45–0.97) between observers was noted in 19 measurements. Conclusion: Measurements evaluating the distance between tibia and fibula in the axial plane 10 mm above the plafond had high intra- and inter-observer reliability. Mean posterior tibio-fibular distance, diastasis, and angular measurement were significantly different between WB and NWB images. | en_US |
dc.identifier.citation | Foot and Ankle Surgery. (2018) | en_US |
dc.identifier.doi | 10.1016/j.fas.2018.10.003 | en_US |
dc.identifier.issn | 14609584 | en_US |
dc.identifier.issn | 12687731 | en_US |
dc.identifier.other | 2-s2.0-85056350556 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/47196 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056350556&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | Reliability of distal tibio-fibular syndesmotic instability measurements using weightbearing and non-weightbearing cone-beam CT | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056350556&origin=inward | en_US |