Publication:
Accuracy and clinical utility of a portable coagulometer in an emergency setting.

dc.contributor.authorChatchawan Rattanabannakiten_US
dc.contributor.authorYongchai Nilanonten_US
dc.contributor.authorChulaluk Komoltrien_US
dc.contributor.authorNarapom Prayoonwiwaten_US
dc.contributor.authorNiphon Poungvarinen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:36:17Z
dc.date.available2018-05-03T08:36:17Z
dc.date.issued2011-02-01en_US
dc.description.abstractThere are limited data concerning accuracy of portable coagulometer in emergency setting. Objective: To evaluate the accuracy of the CoaguChek XS international normalized ratio (INR) monitor compared to the standard laboratory method in emergency department. Emergency room patients who required coagulation test were recruited. Parallel INR measurements between portable coagulometer and standard laboratory were performed. Fifty-five patients with a mean age of 59.1 +/- 15.7 years (20-87) were included. Men constituted 56.4%. Indications for testing were as follows: acute stroke 72.7%; abnormal bleeding 7.3%; taking anticoagulant 7.3%; and others 12.7%. Mean time +/- SD used from blood drawn to INR result report was 65.02 +/- 24.5 minutes for standard laboratory and 1 minute for portable coagulometer. Mean difference of INR result from portable coagulometer and standard laboratory was 0.02 +/- 0.13 and an excellence correlation between INR (r = 0.969) was demonstrated. There was no significant difference between the INR value from the two methods (p = 0.34). The use of portable coagulometer (CoaguChek XS) in emergency setting was accurate and required less time. Acute ischemic stroke patients are likely to benefit from a timely clinical decision making for thrombolysis medication.en_US
dc.identifier.citationJournal of the Medical Association of Thailand = Chotmaihet thangphaet. Vol.94 Suppl 1, (2011)en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-80054831160en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/12665
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80054831160&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleAccuracy and clinical utility of a portable coagulometer in an emergency setting.en_US
dc.typeArticleen_US
dspace.entity.typePublication