Publication:
Utilization of calculated low density lipoprotein cholesterol and measured low density lipoprotein cholesterol in Siriraj Hospital

dc.contributor.authorWanida Wongtirapornen_US
dc.contributor.authorLuksame Wattanamongkonsilen_US
dc.contributor.authorSudcharee Kiartivichen_US
dc.contributor.authorNittaya Mingvivaten_US
dc.contributor.authorSunee Thanakhumtornen_US
dc.contributor.authorNisarat Opartkiattikulen_US
dc.contributor.authorVisanu Thamlikitkulen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherFaculty of Medicine, Thammasat Universityen_US
dc.date.accessioned2018-08-20T07:08:32Z
dc.date.available2018-08-20T07:08:32Z
dc.date.issued2006-11-01en_US
dc.description.abstractA study to determine the utilization of calculated low density lipoprotein (c-LDL) cholesterol and measured low density lipoprotein (m-LDL) cholesterol was conducted. The test results of total cholesterol, triglyceride, HDL-cholesterol and m-LDL-cholesterol from the same individuals aged ≥ 18 years who had the tests done at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital during January to December 2004 were retrieved. The c-LDL-cholesterol level was computed using Friedewald formula. There were two data sets i.e. the m-LDL-cholesterol cut-off level derivation data set (784 subjects) and the m-LDL-cholesterol cut-off level validation data set (800 subjects). The study results revealed: 1) 2.6% of the subjects had blood triglyceride > 400 mg/dl hence c-LDL-cholesterol could not be computed, 2) the correlation between c-LDL-cholesterol levels and m-LDL-cholesterol levels from both data sets was very good (r > 0.95, p < 0.001), 3) the m-LDL-cholesterol levels were usually higher than c-LDL-cholesterol levels, 4) the m-LDL-cholesterol cut-off level derivation data set showed that m-LDL-cholesterol < 87, > 143, > 188, > 233 and > 254 mg/dl were highly correlated with c-LDL-cholesterol < 100, ≥ 100, ≥ 130, ≥ 160 and ≥ 190 mg/dl respectively, 5) an application of m-LDL-cholesterol cut-off levels derived from the m-LDL-cholesterol cut-off level derivation data set to the m-LDL-cholesterol cut-off level validation data set showed that m-LDL-cholesterol < 87, > 143, > 188, > 233 and > 254 mg/dl had accuracy in predicting c-LDL-cholesterol < 100, ≥ 100, ≥ 130, ≥ 160 and ≥ 190 mg/dl of 100%, 99.7%, 100%, 100% and 100% respectively, 6) the use of m-LDL-cholesterol levels as a guide for initiating lipid-lowering agents based on cut-off values of c-LDL-cholesterol levels led to an overuse of lipid-lowering agents in 3.6% to 42.9% of the patients and 7) Nomogram for transforming m-LDL-cholesterol to c-LDL-cholesterol was developed as well as a formula for transforming m-LDL-cholesterol to c-LDL-cholesterol (c-LDL-cholesterol = 0.89 ◇ m-LDL-cholesterol). Therefore, m-LDL-cholesterol assay has a very limited use in managing individuals with suspected or known dyslipidemia. The use of m-LDL-cholesterol level as a guide for management of abnormal LDL-cholesterol conditions leads to an overuse of lipid lowering medications and an enormous expense of m-LDL-cholesterol assay.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.89, No.SUPPL. 5 (2006)en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-33846655419en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/23514
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33846655419&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleUtilization of calculated low density lipoprotein cholesterol and measured low density lipoprotein cholesterol in Siriraj Hospitalen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33846655419&origin=inwarden_US

Files

Collections