Publication:
Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis

dc.contributor.authorThitirat Mantimen_US
dc.contributor.authorKorbua Chaisiwamongkholen_US
dc.contributor.authorKanchana Uraisinen_US
dc.contributor.authorPeter C. Hauseren_US
dc.contributor.authorPrapin Wilairaten_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherUniversitat Baselen_US
dc.contributor.otherMae Fah Luang Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.)en_US
dc.date.accessioned2020-06-02T04:06:28Z
dc.date.available2020-06-02T04:06:28Z
dc.date.issued2020-05-13en_US
dc.description.abstractThis work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter-detector diode (PEDD) device, whilst the conductivity detection employs a capacitively coupled contactless conductivity detector (C4D). The flow-through detection cell is a rectangular acrylic block (ca. 2 × 2 × 1.5 cm) with cylindrical channels in Z-configuration. For the PEDD detector, the LED light source and detector are installed inside the acrylic block. The two electrodes of the C4D are silver conducting ink painted on the PEEK inlet and outlet tubing of the Z-flow cell. The dual-purpose detector is coupled with a sequential injection analysis (SIA) system for simultaneous detection of the absorbance of the orange dye and conductivity of the dissolved oral rehydration salt powder. The detector was also used for sequential measurements of creatinine and the conductivity of human urine samples. The creatinine analysis is based on colorimetric detection of the Jaffé reaction using the PEDD detector, and the conductivity of the urine, as measured by the C4D detector, is expressed in millisiemens (mS cm-1).en_US
dc.identifier.citationMolecules (Basel, Switzerland). Vol.25, No.10 (2020)en_US
dc.identifier.doi10.3390/molecules25102284en_US
dc.identifier.issn14203049en_US
dc.identifier.other2-s2.0-85084787578en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/56112
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85084787578&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleDual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysisen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85084787578&origin=inwarden_US

Files

Collections