Publication:
Cluster signal-to-noise analysis for evaluation of the information content in an image

dc.contributor.authorWarangkana Weerawanichen_US
dc.contributor.authorMayumi Shimizuen_US
dc.contributor.authorYohei Takeshitaen_US
dc.contributor.authorKazutoshi Okamuraen_US
dc.contributor.authorShoko Yoshidaen_US
dc.contributor.authorKazunori Yoshiuraen_US
dc.contributor.otherOkayama Universityen_US
dc.contributor.otherKyushu University Hospitalen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKyushu Universityen_US
dc.contributor.otherFukuoka Dental Collegeen_US
dc.date.accessioned2019-08-23T11:01:40Z
dc.date.available2019-08-23T11:01:40Z
dc.date.issued2018-01-01en_US
dc.description.abstract© 2018 The Authors. Published by the British Institute of Radiology. Objectives: (1) To develop an observer-free method of analysing image quality related to the observer performance in the detection task and (2) to analyse observer behaviour patterns in the detection of small mass changes in cone-beam CT images. Methods: 13 observers detected holes in a Teflon phantom in cone-beam CT images. Using the same images, we developed a new method, cluster signal-to-noise analysis, to detect the holes by applying various cut-off values using ImageJ and reconstructing cluster signal-tonoise curves. We then evaluated the correlation between cluster signal-to-noise analysis and the observer performance test. We measured the background noise in each image to evaluate the relationship with false positive rates (FPRs) of the observers. Correlations between mean FPRs and intra- and interobserver variations were also evaluated. Moreover, we calculated true positive rates (TPRs) and accuracies from background noise and evaluated their correlations with TPRs from observers. Results: Cluster signal-to-noise curves were derived in cluster signal-to-noise analysis. They yield the detection of signals (true holes) related to noise (false holes). This method correlated highly with the observer performance test (R2 = 0.9296). In noisy images, increasing background noise resulted in higher FPRs and larger intra- and interobserver variations. TPRs and accuracies calculated from background noise had high correlation with actual TPRs from observers; R2 was 0.9244 and 0.9338, respectively. Conclusions: Cluster signal-to-noise analysis can simulate the detection performance of observers and thus replace the observer performance test in the evaluation of image quality. Erroneous decision-making increased with increasing background noise.en_US
dc.identifier.citationDentomaxillofacial Radiology. Vol.47, No.1 (2018)en_US
dc.identifier.doi10.1259/dmfr.20170147en_US
dc.identifier.issn0250832Xen_US
dc.identifier.other2-s2.0-85039980336en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45730
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85039980336&origin=inwarden_US
dc.subjectDentistryen_US
dc.subjectMedicineen_US
dc.titleCluster signal-to-noise analysis for evaluation of the information content in an imageen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85039980336&origin=inwarden_US

Files

Collections