Publication:
The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems

dc.contributor.authorSomchai Urapeponen_US
dc.contributor.otherMahidol University, Faculty of Dentistryen_US
dc.date.accessioned2022-08-04T08:30:47Z
dc.date.available2022-08-04T08:30:47Z
dc.date.issued2021-04-01en_US
dc.description.abstractAims: This study aimed to evaluate the marginal and internal discrepancy of the zirconia coping fabricated by two dental computer-aided design-computer-aided manufacturing (CAD-CAM) systems. Settings and Design: In vitro comparative study. Materials and Methods: Twenty zirconia crowns fabricated from inCoris ZI by Cerec InLab CAD-CAM system (Dentsply Sirona Inc, USA) and Ceramill ZI by Ceramill CAD-CAM system (Amann Girrbach, Austria) were measured the discrepancy at six locations using silicone replica technique. Absolute marginal discrepancy (AMD) and marginal gap (MG) represent the marginal discrepancy, and the other four locations at chamfer area, axial wall, cusp tip, and occlusal adaptation represent the internal discrepancy. The gap was measured using an optical light microscope at ×50 magnification. Statistical Analysis Used: The data were analyzed using two-way ANOVA and Game-Howell post hoc test. Results: The statistical analysis showed that the accuracy of zirconia coping depends on CAD-CAM system and the location of measurement. Cerec InLab showed the marginal discrepancy of the coping 119.5 ± 44.8 μm at MG position and 125.3 ± 36.6 μm at AMD position, which was statistically larger than Ceramill system did at 53.0 ± 12.1 μm and 67.2 ± 19.1 μm. On the other hand, the discrepancy in other positions showed no statistical difference between the two CAD-CAM systems. Conclusions: The accuracy of zirconia coping was significant affected by CAD-CAM system and the location of measurement.en_US
dc.identifier.citationJournal of Indian Prosthodontic Society. Vol.21, No.2 (2021), 192-197en_US
dc.identifier.doi10.4103/jips.jips_30_21en_US
dc.identifier.issn19984057en_US
dc.identifier.issn09724052en_US
dc.identifier.other2-s2.0-85105390168en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/76802
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105390168&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleThe marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systemsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105390168&origin=inwarden_US

Files

Collections