Publication:
Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow

dc.contributor.authorChitsanupong Rungsirikunnanen_US
dc.contributor.authorKamonwan Mondeeen_US
dc.contributor.authorGoragoch Gespraserten_US
dc.contributor.authorPhornphop Naiyanetren_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2020-01-27T08:22:39Z
dc.date.available2020-01-27T08:22:39Z
dc.date.issued2019-01-10en_US
dc.description.abstract© 2018 IEEE. Rotary blood pumps were used widely for medical treatment. Ventricular assist device (VAD) is one of the devices which based on rotary blood pump technology. Bridge to recovery (BTR) process is one of the treatment methods. VAD normally generate continuous blood flow. Latest report said that the pulsatile flow is better in blood vessel properties maintaining. However, VAD should not generated high shear stress that will cause the thrombosis. The objective of this study is to compare the hemolysis occur in rotary blood pump during constant speed and pulsatile speed. This study uses MOCK Circulation Loop to simulate the body circulatory system. The continuous flow and pulsatile flow will be compared. The rotary blood pump will be run at 1500 rpm constant speed and 1250-1750rpm, 1000-2000 rpm pulsatile speed at 60 beat per minute. The system was operated for 6 hours. The blood was obtained 1.5 milliliter from the loop every hour. The modified index of hemolysis (MIH) and plasma-free hemoglobin of each speed conditions were compared. The result shown that plasma-free hemoglobin levels in all speed condition increased with the duration of experiment. The MIH shown non significantly difference when the amplitude of pulsatile speed was increase. This experiment was preliminary study. In future work, the computational fluid dynamic software will use to simulated the phenomena inside the rotary blood pump and used for experiment compared.en_US
dc.identifier.citationBMEiCON 2018 - 11th Biomedical Engineering International Conference. (2019)en_US
dc.identifier.doi10.1109/BMEiCON.2018.8609953en_US
dc.identifier.other2-s2.0-85062093882en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/50663
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062093882&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.titleInvestigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flowen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062093882&origin=inwarden_US