Publication:
Improved detection of radiofrequency current-induced minor myocardial injury by cardiac troponin T measurement

dc.contributor.authorKosit Sribhenen_US
dc.contributor.authorKiertijai Bhuripanyoen_US
dc.contributor.authorOngkarn Raungratanaampornen_US
dc.contributor.authorSudcharee Kiartivichen_US
dc.contributor.authorWattana Leowattanaen_US
dc.contributor.authorSuphachai Chaithiraphanen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-09-07T08:58:09Z
dc.date.available2018-09-07T08:58:09Z
dc.date.issued1999-03-01en_US
dc.description.abstractTranscatheter radiofrequency current application in patients with cardiac arrhythmias was reported to be associated with a low rate of an increase in the activity of enzyme creatine kinase (CK) and CK-MB isoenzyme. As the novel heart-specific protein troponin T (cTnT) was shown to be superior to CK and CK-MB in detecting small damage to myocardial tissue in various clinical situations including unstable angina, a comparison of the diagnostic efficiency of these marker proteins to detect myocardial damage was made in 34 patients (mean age 38.3 ± 15.6 years) undergoing radiofrequency (RF) catheter ablation of accessory pathways (n = 17) and atrioventricular nodal reentrant tachycardia (n = 17). Serial measurements of total CK and CK-MB activity before and every 8 hours for 24 hours after ablative procedure were performed with enzymatic and immunoinhibition method, respectively, using automated chemical analyzer Hitachi 717. Serum concentration of cTnT was determined by one-step sandwich ELISA performed on ES 300 analyzer (Boehringer Mannheim). With a median of 7.0 (range 1-39) RF current pulses only 12 (35%) and 10 (29%) of 34 patients showed an increase above the upper limit of normal CK and CK-MB activity, respectively. The peak activity of CK (mean peak = 285.8 ± 517.7 IU/L) occurred at a variable time that infrequently coincided with those of peak CK-MB activity (23.1 ± 8.0 IU/L). By contrast, all except 4 (88%) of 34 patients exhibited a distinct elevation of cTnT concentration (mean peak = 0.56 ± 0.63 ng/ml), with almost all (33) of these 34 patients showed an early peak value at 8 hours postprocedural. There was, on the average, a small but distinct higher relative increase (5.6 times) in cTnT concentration from the upper limit of reference range compared with those of CK (1.5 times) and CK-MB peak activity (0.9 time). In conclusion, cTnT exhibited a minor but distinst elevation in its concentration and demonstrated a higher rate and magnitude of increase following radiofrequency current application than the conventional CK and CK-MB isoenzyme. Measurements of cTnT serum concentration may thus provide a useful test method for assessing the effect of the new transcatheter ablation procedures on myocardial tissue.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.82, No.3 (1999), 256-262en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-0033094065en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/25671
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0033094065&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleImproved detection of radiofrequency current-induced minor myocardial injury by cardiac troponin T measurementen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0033094065&origin=inwarden_US

Files

Collections