Publication:
A novel flow cytometry-based method of analyzing Heinz bodies

dc.contributor.authorD. Palasuwanen_US
dc.contributor.authorA. Palasuwanen_US
dc.contributor.authorA. Charoensappakiten_US
dc.contributor.authorE. Noulsrien_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-21T06:55:13Z
dc.date.accessioned2019-03-14T08:03:01Z
dc.date.available2018-12-21T06:55:13Z
dc.date.available2019-03-14T08:03:01Z
dc.date.issued2017-02-01en_US
dc.description.abstract© 2016 John Wiley & Sons Ltd Introduction: Heinz bodies are important to diagnosing and managing patients. However, microscopic examination of Heinz bodies has several disadvantages, demonstrating the need for a better method. We explored the potential use of flow cytometry to examine Heinz bodies. Methods: Whole-blood samples were collected from patients deficient in G6PD and healthy volunteers. Acetylphenylhydrazine was used to induce formation of Heinz bodies in red blood cells (RBCs). Then, RBCs positive for Heinz bodies were examined using a FACSCanto II cytometer. Results: RBCs treated with acetylphenylhydrazine formed Heinz bodies and emitted a broad spectrum of fluorescence that could be detected by flow cytometry. The maximum emission of fluorescence was observed at 45 min after the incubation with acetylphenylhydrazine. In addition, the fluorescence emitted was stable for at least 72 h. The flow cytometer could detect the RBCs positive for Heinz bodies even if they made up as little as 0.1% of the total RBC population. Furthermore, the percentage and number, respectively, of RBCs positive for Heinz bodies in G6PD-deficient patients and normal donors exhibited a mean ± standard deviation (SD) of 68.9 ± 27.5 vs. 50.9 ± 28.6 and 96 014 ±35 732 cells/μL vs. 74 688 ± 36 514 cells/μL. Conclusion: Heinz bodies induced by acetylphenylhydrazine emit fluorescence, and this fluorescence could be examined using flow cytometry. Our study suggests the potential use of the developed method to investigate the formation of Heinz bodies in clinical samples.en_US
dc.identifier.citationInternational Journal of Laboratory Hematology. Vol.39, No.1 (2017), 68-75en_US
dc.identifier.doi10.1111/ijlh.12576en_US
dc.identifier.issn1751553Xen_US
dc.identifier.issn17515521en_US
dc.identifier.other2-s2.0-85007159367en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/41979
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85007159367&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleA novel flow cytometry-based method of analyzing Heinz bodiesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85007159367&origin=inwarden_US

Files