Publication: Using a combination of 2- planes in ultrasonographic guidance for internal jugular vein cannulation. A prospective sequential comparison
dc.contributor.author | Chinakorn Sujimongkol | en_US |
dc.contributor.author | Pattarapron Wongput | en_US |
dc.contributor.author | Suntharee Wichakhrueang | en_US |
dc.contributor.author | Somsri Daochai | en_US |
dc.contributor.other | Muang Loei Ram Hospital | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-11-23T10:08:14Z | |
dc.date.available | 2018-11-23T10:08:14Z | |
dc.date.issued | 2015-01-01 | en_US |
dc.description.abstract | © 2014 IEEE. This study has been launched that will assess whether a novel imaging-guided for internal jugular vein cannulation is beneficial to enhance patient safety and feasible to daily practice for internal jugular vein cannulation. The effectiveness and accuracy of a prospective before (phase 1) versus after (phase 2) was compared, whereby single plane approach was employed in the first phase and the second one was approached by a fusion of short and long axis technique. The result found an intervention practiced on a combination of imaging planes had a significantly higher the success rate at the first attempt [Odd ratio: 3.5, (95% CI: 1.1-10.9), p = 0.03]. A novel guidance approach is easy-to-implement solutions for improving safety. | en_US |
dc.identifier.citation | BMEiCON 2014 - 7th Biomedical Engineering International Conference. (2015) | en_US |
dc.identifier.doi | 10.1109/BMEiCON.2014.7017385 | en_US |
dc.identifier.other | 2-s2.0-84923039478 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/35948 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84923039478&origin=inward | en_US |
dc.subject | Engineering | en_US |
dc.title | Using a combination of 2- planes in ultrasonographic guidance for internal jugular vein cannulation. A prospective sequential comparison | en_US |
dc.type | Conference Paper | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84923039478&origin=inward | en_US |