Publication: Low-CD4+ T-lymphocyte blood samples for external quality assessment of CD4 testing in resource-poor settings
| dc.contributor.author | Egarit Noulsri | en_US |
| dc.contributor.author | Surada Lerdwana | en_US |
| dc.contributor.author | Kovit Pattanapanyasat | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.date.accessioned | 2018-11-09T02:03:30Z | |
| dc.date.available | 2018-11-09T02:03:30Z | |
| dc.date.issued | 2014-01-01 | en_US |
| dc.description.abstract | © 2014, Springer-Verlag Berlin Heidelberg. External quality assessment (EQA) of CD4 testing is important for clinically monitoring of patients with HIV/AIDS. EQA materials are limited to blood samples from normal blood donors with normal CD4+ T-lymphocyte levels. This study aimed to develop low-CD4+ T-lymphocyte blood samples for CD4 EQA. CD4+ T-lymphocyte-depleted blood samples were prepared using a magnetic bead separation technique. These CD4+ T-lymphocyte-depleted blood samples were mixed with undepleted whole blood samples to obtain low-CD4+ T-lymphocyte blood samples. The percentage and the number of CD4+ T-lymphocytes were determined using a flow cytometer. An evaluation study of this low-CD4+ T-lymphocyte blood sample was performed by sending to participating laboratories to investigate the potential use as CD4 EQA material. Our results showed that a magnetic separation technique could be used to prepare low-CD4+ T-lymphocyte blood samples. CD4+ T-lymphocytes in the low-CD4+ T-lymphocyte blood samples ranged from 15 % to 18 % and 160–300 cell/μl, respectively. In addition, CD4 testing of our low-CD4+ T-lymphocyte blood samples could be achieved following both the single- and the dual-platform flow cytometric approaches. A pilot EQA investigation revealed that the CV values of the number and percentage of CD4+ T-lymphocytes were 14 % and 10 %, respectively. Having the low-CD4+ T-lymphocyte blood samples in our CD4 EQA program should ensure reliability and credibility of CD4 testing in Thailand and other resource-poor countries. | en_US |
| dc.identifier.citation | Accreditation and Quality Assurance. Vol.19, No.6 (2014), 423-431 | en_US |
| dc.identifier.doi | 10.1007/s00769-014-1086-z | en_US |
| dc.identifier.issn | 09491775 | en_US |
| dc.identifier.other | 2-s2.0-84912022348 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/33581 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84912022348&origin=inward | en_US |
| dc.subject | Chemical Engineering | en_US |
| dc.subject | Chemistry | en_US |
| dc.subject | Engineering | en_US |
| dc.subject | Physics and Astronomy | en_US |
| dc.title | Low-CD4+ T-lymphocyte blood samples for external quality assessment of CD4 testing in resource-poor settings | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84912022348&origin=inward | en_US |