Publication:
Low-CD4+ T-lymphocyte blood samples for external quality assessment of CD4 testing in resource-poor settings

dc.contributor.authorEgarit Noulsrien_US
dc.contributor.authorSurada Lerdwanaen_US
dc.contributor.authorKovit Pattanapanyasaten_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-09T02:03:30Z
dc.date.available2018-11-09T02:03:30Z
dc.date.issued2014-01-01en_US
dc.description.abstract© 2014, Springer-Verlag Berlin Heidelberg. External quality assessment (EQA) of CD4 testing is important for clinically monitoring of patients with HIV/AIDS. EQA materials are limited to blood samples from normal blood donors with normal CD4+ T-lymphocyte levels. This study aimed to develop low-CD4+ T-lymphocyte blood samples for CD4 EQA. CD4+ T-lymphocyte-depleted blood samples were prepared using a magnetic bead separation technique. These CD4+ T-lymphocyte-depleted blood samples were mixed with undepleted whole blood samples to obtain low-CD4+ T-lymphocyte blood samples. The percentage and the number of CD4+ T-lymphocytes were determined using a flow cytometer. An evaluation study of this low-CD4+ T-lymphocyte blood sample was performed by sending to participating laboratories to investigate the potential use as CD4 EQA material. Our results showed that a magnetic separation technique could be used to prepare low-CD4+ T-lymphocyte blood samples. CD4+ T-lymphocytes in the low-CD4+ T-lymphocyte blood samples ranged from 15 % to 18 % and 160–300 cell/μl, respectively. In addition, CD4 testing of our low-CD4+ T-lymphocyte blood samples could be achieved following both the single- and the dual-platform flow cytometric approaches. A pilot EQA investigation revealed that the CV values of the number and percentage of CD4+ T-lymphocytes were 14 % and 10 %, respectively. Having the low-CD4+ T-lymphocyte blood samples in our CD4 EQA program should ensure reliability and credibility of CD4 testing in Thailand and other resource-poor countries.en_US
dc.identifier.citationAccreditation and Quality Assurance. Vol.19, No.6 (2014), 423-431en_US
dc.identifier.doi10.1007/s00769-014-1086-zen_US
dc.identifier.issn09491775en_US
dc.identifier.other2-s2.0-84912022348en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/33581
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84912022348&origin=inwarden_US
dc.subjectChemical Engineeringen_US
dc.subjectChemistryen_US
dc.subjectEngineeringen_US
dc.subjectPhysics and Astronomyen_US
dc.titleLow-CD4+ T-lymphocyte blood samples for external quality assessment of CD4 testing in resource-poor settingsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84912022348&origin=inwarden_US

Files

Collections