Publication: Factors affecting standardized uptake value (SUV) of positron emission tomography (PET) imaging with<sup>18</sup>F-FDG
Issued Date
2010-01-01
Resource Type
ISSN
01252208
01252208
01252208
Other identifier(s)
2-s2.0-77249083742
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Journal of the Medical Association of Thailand. Vol.93, No.1 (2010), 108-114
Suggested Citation
Kanyalak Wiyaporn, Chiraporn Tocharoenchai, Pawana Pusuwan, Tawatchai Ekjeen, Suraphong Leaungwutiwong, Suchera Thanyarak Factors affecting standardized uptake value (SUV) of positron emission tomography (PET) imaging with<sup>18</sup>F-FDG. Journal of the Medical Association of Thailand. Vol.93, No.1 (2010), 108-114. Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/29857
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Factors affecting standardized uptake value (SUV) of positron emission tomography (PET) imaging with<sup>18</sup>F-FDG
Other Contributor(s)
Abstract
Objective: The purpose of the study was to study factors affecting SUV of PET imaging with 18F-FDG. Material and Method: PET/CT Biograph 64 was used to acquire the data. A NEMA PET phantom with 6 spheres varying in diameter from 10 to 37 mm was used to mimic the human body and tumors. Background activity of 18F in the phantom was 0.14 μCi/ml and tumor-to-background ratios (TBR) of 2:1, 5:1 and 10:1 were studied. For each TBR, thirty sinograms were acquired with 3-min scan durations. Different scan durations varying from 3 to 20 min using a TBR of 5:1were studied and three datasets of each scan time were collected. Sinograms were reconstructed using the Ordered Subset Expectation Maximization (OSEM) algorithm with 5 mm Full-Width-at-Half-Maximum (FWHM) Gaussian filtering. Sinograms at TBR of 5:1 were reconstructed by varying the number of iterative updates of OSEM (N) from 8 to 168 and SUVavg and SUVmax were measured. The percentage of underestimation of SUVs was used to study the effect of tumor size and TBR. Intraclass correlation coefficient (ICC) was used to test the reliability of SUVmax with different scan durations. Results: The results showed that both the SUVavg and SUVmax rapidly increased when N was < 48 and slightly increased afterwards. At TBRs ranging from 2:1 to 10:1, the percentages of underestimation of SUVmax ranged from 8.17 to 22.46 and that of SUVavg were ranged from 41.44 to 52.33 for 37-mm sphere and from 40.38 to 54.52 and from 48.97 to 67.73 for 10-mm sphere respectively. Different scan durations gave reliable SUVsmax with ICC of 0.996. Conclusion: SUVs increased as N increased. The percentage of underestimation of the SUV depended on tumor size and TBR. Scan duration did not affect SUVs.