Publication:
A 4-year pilot study on the efficacy and safety of Implanon®, a single-rod hormonal contraceptive implant, in healthy women in Thailand

dc.contributor.authorO. Kiriwaten_US
dc.contributor.authorA. Patanayindeeen_US
dc.contributor.authorS. Koetsawangen_US
dc.contributor.authorT. Korveren_US
dc.contributor.authorH. J.T. Coelingh Benninken_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherRajavithi Hospitalen_US
dc.contributor.otherMerck Sharp & Dohme, Netherlandsen_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2018-07-04T08:17:27Z
dc.date.available2018-07-04T08:17:27Z
dc.date.issued1998-01-01en_US
dc.description.abstractObjective To investigate the contraceptive efficacy, safety and acceptability of a new single-rod, progestogen-only contraceptive implant (Implanon®). Methods In an open, non-comparative pilot study, 100 healthy women received a contraceptive implant containing the progestogen etonogestrel (3-ketodesogestrel) for 2 years with an optional extension up to 4 years. Results Subjects were exposed to Implanon for 296.1 woman-years. There were no pregnancies during the study. Per 90-day reference period, the median number of bleeding-spotting days was 10 and the median number of bleeding-spotting episodes was 2. Amenorrhea occurred in 24-39% of subjects during the first 2 years and in about 20% in those who continued in the 3rd and 4th years. The most common drug-related adverse event was headache (7%). A slight increase in body mass index was observed. Only a few subjects discontinued treatment early, due to bleeding irregularities (6%) or amenorrhea (1%). The cumulative discontinuation rates were 13.4% after 2 years, 25.3% after 3 years and 28.0% after 4 years of use. Within 3 months of implant removal, six normal pregnancies occurred, indicating a rapid return of fertility. The average time taken for insertion of the implant was 0.5 min, compared with 2.5 min for removal. Conclusions Implanon demonstrated excellent contraceptive efficacy and was well tolerated during up to 4 years of use. The vaginal bleeding pattern was variable and was characterized by relatively few bleeding events, but proved acceptable to most subjects. Because of its single-rod design, Implanon was quickly inserted and removed without complications.en_US
dc.identifier.citationEuropean Journal of Contraception and Reproductive Health Care. Vol.3, No.2 (1998), 85-91en_US
dc.identifier.doi10.3109/13625189809051409en_US
dc.identifier.issn13625187en_US
dc.identifier.other2-s2.0-0032091002en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/18617
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0032091002&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleA 4-year pilot study on the efficacy and safety of Implanon®, a single-rod hormonal contraceptive implant, in healthy women in Thailanden_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0032091002&origin=inwarden_US

Files

Collections