Publication: Quantification of the variability associated with repeat measurements of left ventricular two-dimensional global longitudinal strain in a real-world setting
Issued Date
2014-01-01
Resource Type
ISSN
10976795
08947317
08947317
Other identifier(s)
2-s2.0-84896546679
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Journal of the American Society of Echocardiography. Vol.27, No.1 (2014), 50-54
Suggested Citation
Salvatore P. Costa, Timothy A. Beaver, Joyce L. Rollor, Pantila Vanichakarn, Patrick C. Magnus, Robert T. Palac Quantification of the variability associated with repeat measurements of left ventricular two-dimensional global longitudinal strain in a real-world setting. Journal of the American Society of Echocardiography. Vol.27, No.1 (2014), 50-54. doi:10.1016/j.echo.2013.08.021 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/34676
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Quantification of the variability associated with repeat measurements of left ventricular two-dimensional global longitudinal strain in a real-world setting
Other Contributor(s)
Abstract
Background Global longitudinal strain (GLS) derived from two-dimensional speckle-tracking is an emerging technology, but lack of industry standards limits its application. Prior studies support using this tool to identify subclinical disease through serial changes, but the variability introduced by a change in vendor or reader is not well defined. Methods Fifty study subjects were prospectively identified to include four subgroups to ensure a broad range of GLS: normal (n = 20), left ventricular hypertrophy (n = 10), ST-segment elevation myocardial infarction (n = 10), and systolic heart failure (n = 10). Raw data were obtained using equipment from two vendors during the same session, and GLS was analyzed using an offline workstation. Intraobserver and interobserver variation was measured using correlation coefficients, intraclass correlation coefficients, and Bland-Altman plots. Results GLS measurements were highly reproducible by the same reader or a different reader using vendor 1 and vendor 2 or comparing vendors (correlation coefficients and intraclass correlation coefficients ≥ 0.95). However, the Bland-Altman plots suggested that the variation in repeat GLS measurements may range from ± 2% to ± 5% on the basis of a change in vendor, reader, or both. Conclusions The expected variation in GLS measurements associated with a change in vendor, reader, or both should be considered when making conclusions about significant changes in serial measurements. ©2014 by the American Society of Echocardiography.
