Capillary surface modification using millimolar levels of aminosilane reagent for highly efficient separation of phenolic acids and flavonols by capillary electrophoresis with UV detection

dc.contributor.authorHemwech P.
dc.contributor.authorObma A.
dc.contributor.authorDetsangiamsak S.
dc.contributor.authorWirasate S.
dc.contributor.authorWilairat P.
dc.contributor.authorChantiwas R.
dc.contributor.otherMahidol University
dc.date.accessioned2023-07-08T18:00:52Z
dc.date.available2023-07-08T18:00:52Z
dc.date.issued2023-01-01
dc.description.abstractIntroduction: Phytochemical analysis of phenolic acids and flavonols poses a challenge, necessitating the development of an efficient separation method. This facilitates the quantification of these compounds, yielding valuable insights into their benefits. Objective: To develop a highly effective separation of phenolic acids and flavonols by capillary electrophoresis and ultraviolet (UV) detection through the modification of the capillary surface using 3-aminopropyltriethoxysilane (APTES) at millimolar concentrations. Methods: The capillary surface is modified with 0.36 mM-APTES solution. The electrolyte is 20.0 mM borate buffer (pH 9.0). Separation performance (plate number N, resolution Rs), stability, and reproducibility of the coating procedure are evaluated using the analysis of phenolic acids, rutin and quercetin. Results: The modified capillary provided efficient separation with plate numbers N ≥ 1.0 × 104 m−1 and resolution Rs ≥ 0.8 for all pairs of adjacent peaks of the separation of five selected phenolic acids, rutin, quercetin, caffeine and methylparaben (as internal standard). The precisions of the relative migration times for 17 consecutive analyses of samples over 3 h were 1% relative standard deviation (RSD) for rutin and 7% RSD for quercetin. The analysis of rutin and quercetin in 12 dietary supplement product samples only required a simple dilution step for sample preparation. Conclusion: A straightforward modification technique utilising millimolar concentrations of APTES resulted in highly efficient separation of phenolic acids, rutin and quercetin, accompanied by high precision and surface stability. The modified capillary proved successful in analysing rutin and quercetin content in dietary supplements.
dc.identifier.citationPhytochemical Analysis (2023)
dc.identifier.doi10.1002/pca.3250
dc.identifier.eissn10991565
dc.identifier.issn09580344
dc.identifier.scopus2-s2.0-85163109892
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/87812
dc.rights.holderSCOPUS
dc.subjectAgricultural and Biological Sciences
dc.titleCapillary surface modification using millimolar levels of aminosilane reagent for highly efficient separation of phenolic acids and flavonols by capillary electrophoresis with UV detection
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85163109892&origin=inward
oaire.citation.titlePhytochemical Analysis
oairecerif.author.affiliationMahidol University