Development of a high-throughput flow cytometric neutralization assay to screen for human enterovirus A71 (EVA71) neutralizing antibodies

dc.contributor.authorWongsa A.
dc.contributor.authorPriengprom T.
dc.contributor.authorSaelee J.
dc.contributor.authorPhawong C.
dc.contributor.authorTassaneetrithep B.
dc.contributor.otherMahidol University
dc.date.accessioned2023-10-18T18:01:30Z
dc.date.available2023-10-18T18:01:30Z
dc.date.issued2023-12-01
dc.description.abstractThe conventional method for screening neutralizing antibodies to human enterovirus A71 (EVA71) (microneutralization assay) is time consuming and requires an expert to perform manual evaluation. An automated neutralization assay could shorten the testing time, improve reproducibility, and provide automatic analysis. This study aimed to develop a high-throughput flow cytometric neutralization assay to screen for EVA71 neutralizing antibodies, and to develop quality control materials to ensure accurate testing. The results of this study demonstrate the high potential viability of the proposed flow cytometric method. Compared to the standard method, the flow cytometric method was shown to require a smaller sample volume, provide a much faster turnaround time, provide a rapid result for interpreting the neutralizing antibody level, and allow for possible quantification of results. The observed drawbacks of the proposed method include higher cost per test, longer hands-on time, and lower sensitivity in low titer conditions, which could lead to false negative results. The developed quality control materials were demonstrated to be effective and storable for 1 month. These results pave the way for the optimization and implementation of an automated neutralization assay to screen for neutralizing antibodies not only against EVA71, but also against other viruses in the enterovirus genus.
dc.identifier.citationJournal of Virological Methods Vol.322 (2023)
dc.identifier.doi10.1016/j.jviromet.2023.114828
dc.identifier.eissn18790984
dc.identifier.issn01660934
dc.identifier.scopus2-s2.0-85173268589
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/90501
dc.rights.holderSCOPUS
dc.subjectImmunology and Microbiology
dc.titleDevelopment of a high-throughput flow cytometric neutralization assay to screen for human enterovirus A71 (EVA71) neutralizing antibodies
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85173268589&origin=inward
oaire.citation.titleJournal of Virological Methods
oaire.citation.volume322
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationFaculty of Medicine, Thammasat University

Files

Collections