Determination of ivermectin in plasma and whole blood using LC-MS/MS

dc.contributor.authorKaewkhao N.
dc.contributor.authorHanpithakpong W.
dc.contributor.authorTarning J.
dc.contributor.authorBlessborn D.
dc.contributor.correspondenceKaewkhao N.
dc.contributor.otherMahidol University
dc.date.accessioned2024-10-16T18:18:17Z
dc.date.available2024-10-16T18:18:17Z
dc.date.issued2024-01-01
dc.description.abstractBackground: Ivermectin is a widely used drug for the treatment of helminthiasis and filariasis worldwide, and it has also shown promise for malaria elimination through its potent mosquito-lethal activity. The objective of this study was to develop and validate a high-throughput and sensitive method to quantify ivermectin in plasma and whole blood samples, using automated sample extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods: Phospholipids were removed in patient whole blood (100 µl) and plasma (100 µl) samples using a 96-well plate Hybrid-solid phase extraction technique. Ivermectin and its isotope-labelled internal standard (ivermectin-D2) were separated on an Agilent Poroshell 120 EC-C18 50mm × 3.0mm I.D. 2.7µm, using a mobile phase of acetonitrile: ammonium formate 2 mM containing 0.5% formic acid (90: 10, v/v). Detection was performed using a triple quadrupole mass spectrometer in the positive ionization mode. Results: The method was validated in the concentration range 0.970 - 384 ng/ml in both plasma and whole blood matrices. Intra- and inter-batch precisions during the validation were below 15%. There was no carryover or matrix effects detected. Ivermectin is a stable compound and results showed no degradation in the different stability tests. Conclusions: The validated method proved to have high sensitivity and precision, good selectivity and to be suitable for clinical application or laboratory quantification of ivermectin in plasma or whole blood samples.
dc.identifier.citationWellcome Open Research Vol.9 (2024)
dc.identifier.doi10.12688/wellcomeopenres.20613.2
dc.identifier.eissn2398502X
dc.identifier.scopus2-s2.0-85205737374
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/101612
dc.rights.holderSCOPUS
dc.subjectBiochemistry, Genetics and Molecular Biology
dc.subjectMedicine
dc.titleDetermination of ivermectin in plasma and whole blood using LC-MS/MS