Closed–loop oxygen control improves oxygenation in pediatric patients under high–flow nasal oxygen—A randomized crossover study

dc.contributor.authorSandal O.
dc.contributor.authorCeylan G.
dc.contributor.authorTopal S.
dc.contributor.authorHepduman P.
dc.contributor.authorColak M.
dc.contributor.authorNovotni D.
dc.contributor.authorSoydan E.
dc.contributor.authorKaraarslan U.
dc.contributor.authorAtakul G.
dc.contributor.authorSchultz M.J.
dc.contributor.authorAğın H.
dc.contributor.otherMahidol University
dc.date.accessioned2023-06-18T17:40:34Z
dc.date.available2023-06-18T17:40:34Z
dc.date.issued2022-11-16
dc.description.abstractBackground: We assessed the effect of a closed–loop oxygen control system in pediatric patients receiving high–flow nasal oxygen therapy (HFNO). Methods: A multicentre, single–blinded, randomized, and cross–over study. Patients aged between 1 month and 18 years of age receiving HFNO for acute hypoxemic respiratory failure (AHRF) were randomly assigned to start with a 2–h period of closed–loop oxygen control or a 2–h period of manual oxygen titrations, after which the patient switched to the alternative therapy. The endpoints were the percentage of time spent in predefined SpO2 ranges (primary), FiO2, SpO2/FiO2, and the number of manual adjustments. Findings: We included 23 patients, aged a median of 18 (3–26) months. Patients spent more time in a predefined optimal SpO2 range when the closed–loop oxygen controller was activated compared to manual oxygen titrations [91⋅3% (IQR 78⋅4–95⋅1%) vs. 63⋅0% (IQR 44⋅4–70⋅7%)], mean difference [28⋅2% (95%–CI 20⋅6–37⋅8%); P < 0.001]. Median FiO2 was lower [33⋅3% (IQR 26⋅6–44⋅6%) vs. 42⋅6% (IQR 33⋅6–49⋅9%); P = 0.07], but median SpO2/FiO2 was higher [289 (IQR 207–348) vs. 194 (IQR 98–317); P = 0.023] with closed–loop oxygen control. The median number of manual adjustments was lower with closed–loop oxygen control [0⋅0 (IQR 0⋅0–0⋅0) vs. 0⋅5 (IQR 0⋅0–1⋅0); P < 0.001]. Conclusion: Closed-loop oxygen control improves oxygenation therapy in pediatric patients receiving HFNO for AHRF and potentially leads to more efficient oxygen use. It reduces the number of manual adjustments, which may translate into decreased workloads of healthcare providers. Clinical trial registration: [www.ClinicalTrials.gov], identifier [NCT 05032365].
dc.identifier.citationFrontiers in Medicine Vol.9 (2022)
dc.identifier.doi10.3389/fmed.2022.1046902
dc.identifier.eissn2296858X
dc.identifier.scopus2-s2.0-85143228542
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/85374
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleClosed–loop oxygen control improves oxygenation in pediatric patients under high–flow nasal oxygen—A randomized crossover study
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85143228542&origin=inward
oaire.citation.titleFrontiers in Medicine
oaire.citation.volume9
oairecerif.author.affiliationUniversity of Health Sciences
oairecerif.author.affiliationHamilton Medical AG
oairecerif.author.affiliationMahidol University
oairecerif.author.affiliationNuffield Department of Medicine
oairecerif.author.affiliationAmsterdam UMC - University of Amsterdam

Files

Collections