Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants
7
item.page.dc.date.issued
2025-01-01
item.page.dc.type
item.page.dc.identifier.eissn
19326203
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-105026115970
item.page.dc.identifier.pmid
41452929
item.page.oaire.citation.title
Plos One
item.page.oaire.citation.volume
20
item.page.oaire.citation.issue
12
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Plos One Vol.20 No.12 (2025) , e0339618
punsarn.item.page.citation
Taweekitikul P., Abdu Aliyu A.A., Jinakul N., Wongrakpanich A., Puncreobutr C., Khamwannah J., Lohwongwatana B., Tantavisut S. Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants. Plos One Vol.20 No.12 (2025) , e0339618. doi:10.1371/journal.pone.0339618 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/113964
item.page.dc.title
Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.correspondence
item.page.dc.contributor.other
item.page.dc.description.abstract
Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.