Smartphone multiplex microcapillary diagnostics using Cygnus: Development and evaluation of rapid serotype-specific NS1 detection with dengue patient samples

dc.contributor.authorNeeds S.H.
dc.contributor.authorSirivisoot S.
dc.contributor.authorJegouic S.
dc.contributor.authorPrommool T.
dc.contributor.authorLuangaram P.
dc.contributor.authorSrisawat C.
dc.contributor.authorSriraksa K.
dc.contributor.authorLimpitikul W.
dc.contributor.authorMairiang D.
dc.contributor.authorMalasit P.
dc.contributor.authorAvirutnan P.
dc.contributor.authorPuttikhunt C.
dc.contributor.authorEdwards A.D.
dc.contributor.otherMahidol University
dc.date.accessioned2023-06-18T17:52:44Z
dc.date.available2023-06-18T17:52:44Z
dc.date.issued2022-04-01
dc.description.abstractLaboratory diagnosis of dengue virus (DENV) infection including DENV serotyping requires skilled labor and well-equipped settings. DENV NS1 lateral flow rapid test (LFT) provides simplicity but lacks ability to identify serotype. A simple, economical, point-of-care device for serotyping is still needed. We present a gravity driven, smartphone compatible, microfluidic device using microcapillary film (MCF) to perform multiplex serotype-specific immunoassay detection of dengue virus NS1. A novel device–termed Cygnus–with a stackable design allows analysis of 1 to 12 samples in parallel in 40 minutes. A sandwich enzyme immunoassay was developed to specifically detect NS1 of all four DENV serotypes in one 60-μl plasma sample. This test aims to bridge the gap between rapid LFT and laboratory micro-plate ELISAs in terms of sensitivity, usability, accessibility and speed. The Cygnus NS1 assay was evaluated with retrospective undiluted plasma samples from 205 DENV infected patients alongside 50 febrile illness negative controls. Against the gold standard RT-PCR, clinical sensitivity for Cygnus was 82% in overall (with 78, 78, 80 and 76% for DENV1-4, respectively), comparable to an in-house serotyping NS1 microplate ELISA (82% vs 83%) but superior to commercial NS1-LFT (82% vs 74%). Specificity of the Cygnus device was 86%, lower than that of NS1-microplate ELISA and NS1-LFT (100% and 98%, respectively). For Cygnus positive samples, identification of DENV serotypes DENV2-4 matched those by RT-PCR by 100%, but for DENV1 capillaries false positives were seen, suggesting an improved DENV1 capture antibody is needed to increase specificity. Overall performance of Cygnus showed substantial agreement to NS1-microplate ELISA (κ = 0.68, 95%CI 0.58– 0.77) and NS1-LFT (κ = 0.71, 95%CI 0.63–0.80). Although further refinement for DENV-1 NS1 detection is needed, the advantages of multiplexing and rapid processing time, this Cygnus device could deliver point-of-care NS1 antigen testing including serotyping for timely DENV diagnosis for epidemic surveillance and outbreak prediction.
dc.identifier.citationPLoS Neglected Tropical Diseases Vol.16 No.4 (2022)
dc.identifier.doi10.1371/journal.pntd.0010266
dc.identifier.eissn19352735
dc.identifier.issn19352727
dc.identifier.pmid35389998
dc.identifier.scopus2-s2.0-85127755511
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/85989
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleSmartphone multiplex microcapillary diagnostics using Cygnus: Development and evaluation of rapid serotype-specific NS1 detection with dengue patient samples
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85127755511&origin=inward
oaire.citation.issue4
oaire.citation.titlePLoS Neglected Tropical Diseases
oaire.citation.volume16
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationCapillary Film Technology Ltd.
oairecerif.author.affiliationChulalongkorn University
oairecerif.author.affiliationSongkhla Hospital
oairecerif.author.affiliationKhon Kaen Regional Hospital
oairecerif.author.affiliationUniversity of Reading
oairecerif.author.affiliationThailand National Center for Genetic Engineering and Biotechnology

Files