Dual-mode portable electrochemical aptasensor for monitoring urinary neutrophil gelatinase-associated lipocalin (NGAL) biomarker

dc.contributor.authorRuankham W.
dc.contributor.authorPhopin K.
dc.contributor.authorSamarnjit J.
dc.contributor.authorTantimongcolwat T.
dc.contributor.correspondenceRuankham W.
dc.contributor.otherMahidol University
dc.date.accessioned2026-02-06T18:10:29Z
dc.date.available2026-02-06T18:10:29Z
dc.date.issued2026-02-01
dc.description.abstractNeutrophil gelatinase-associated lipocalin (NGAL) is significantly released in the serum and urine of acute kidney injury (AKI) patients as early as 2 h after the onset of renal damage, making it a potential candidate as an early biomarker for AKI monitoring and prognosis. An electrochemical aptasensor for NGAL detection was developed within a wide linear range of 5.0–320.0 ng/mL in PBS solution and a limit range of 5.0–25.0 ng/mL in artificial urine. Limits of detection (LODs) of square wave voltammetry (SWV) mode in PBS and artificial urine were at 0.81 and 4.59 ng/mL, respectively, while electrochemical impedance spectroscopy (EIS) measurements were observed at 0.48 and 5.27 ng/mL in PBS and artificial urine samples, respectively. Particularly, the dual measurement mode integrated with a multiple linear regression (MLR) model achieved an improved LOD of 3.27 ng/mL in urine matrix. NGAL aptasensor offered admirable recovery performance in a range of 93.0% and 126.0% with the relative standard deviations (RSDs) between 1.162% and 4.625%. The aptasensor was highly selective for NGAL across urinary matrices, while it tolerated potential interferences (i.e., IGFBP-7, BSA, ascorbic acid, and glucose) and offered stable performance for up to 14–21 days of storage. Its label-free, portable, and sensitive performance makes it a promising candidate for NGAL point-of-care testing (POCT) applications, enabling rapid and reliable detection of AKI status in clinical and field settings.
dc.identifier.citationTalanta Vol.298 (2026)
dc.identifier.doi10.1016/j.talanta.2025.129047
dc.identifier.eissn18733573
dc.identifier.issn00399140
dc.identifier.pmid41192243
dc.identifier.scopus2-s2.0-105020961336
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/114380
dc.rights.holderSCOPUS
dc.subjectChemistry
dc.titleDual-mode portable electrochemical aptasensor for monitoring urinary neutrophil gelatinase-associated lipocalin (NGAL) biomarker
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105020961336&origin=inward
oaire.citation.titleTalanta
oaire.citation.volume298
oairecerif.author.affiliationMahidol University
oairecerif.author.affiliationFaculty of Engineering

Files

Collections