A Novel Connector for Intraoperative Nerve Monitoring Probes in Endoscopic Thyroidectomy: Comparative Efficacy and Preclinical Evaluation in a Porcine Model
| dc.contributor.author | Chairat P. | |
| dc.contributor.author | Pithuksurachai P. | |
| dc.contributor.author | Chongkolwatana C. | |
| dc.contributor.author | Wechakarn P. | |
| dc.contributor.author | Akkhawattanangkul Y. | |
| dc.contributor.author | Hommuang K. | |
| dc.contributor.author | Charoonrut P. | |
| dc.contributor.author | Jamikorn T. | |
| dc.contributor.author | Anuwong A. | |
| dc.contributor.author | Wu C.W. | |
| dc.contributor.author | Randolph G.W. | |
| dc.contributor.author | Russell M.D. | |
| dc.contributor.author | Abdelhamid Ahmed A.H. | |
| dc.contributor.author | Maneeprasopchoke P. | |
| dc.contributor.correspondence | Chairat P. | |
| dc.contributor.other | Mahidol University | |
| dc.date.accessioned | 2026-02-06T18:19:27Z | |
| dc.date.available | 2026-02-06T18:19:27Z | |
| dc.date.issued | 2026-01-01 | |
| dc.description.abstract | Background: This study aimed to develop a connector that adapts standard endoscopic instruments into functional nerve stimulator probes. Methods: The connector underwent engineering validation in a laboratory and preclinical testing using a porcine model. A handheld standard stimulator probe served as the control. The experimental group consisted of a long monopolar probe and two connector-adapted probes. Recurrent laryngeal nerve (RLN) and vagus nerves were stimulated to compare the efficacy and safety of the adapted probes with the standard probe. Results: The connector, when coupled to endoscopic instruments, did not show a statistically significant difference in electromyographic (EMG) amplitude at 1 mA stimulation compared with the standard probe. Safety analysis showed no significant hemodynamic effects. Conclusion: This proof-of-concept study demonstrates that the developed connector, when paired with endoscopic instruments, enables reliable nerve identification and preservation during endoscopic thyroid surgery, with favorable efficacy and safety profiles. | |
| dc.identifier.citation | Head and Neck (2026) | |
| dc.identifier.doi | 10.1002/hed.70159 | |
| dc.identifier.eissn | 10970347 | |
| dc.identifier.issn | 10433074 | |
| dc.identifier.scopus | 2-s2.0-105026586804 | |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/114542 | |
| dc.rights.holder | SCOPUS | |
| dc.subject | Medicine | |
| dc.title | A Novel Connector for Intraoperative Nerve Monitoring Probes in Endoscopic Thyroidectomy: Comparative Efficacy and Preclinical Evaluation in a Porcine Model | |
| dc.type | Article | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105026586804&origin=inward | |
| oaire.citation.title | Head and Neck | |
| oairecerif.author.affiliation | Harvard Medical School | |
| oairecerif.author.affiliation | Mahidol University | |
| oairecerif.author.affiliation | Siriraj Hospital | |
| oairecerif.author.affiliation | School of Medicine | |
| oairecerif.author.affiliation | Police General Hospital |