Effectiveness of prophylactic double-looped wiring in cementless Hip arthroplasty: A biomechanical study in osteoporotic bone model using impaction simulation system

dc.contributor.authorWongsak S.
dc.contributor.authorSa-ngasoongsong P.
dc.contributor.authorPinitkwamdee S.
dc.contributor.authorThongchuea N.
dc.contributor.authorPrasai A.B.
dc.contributor.authorWarinsiriruk E.
dc.contributor.authorJarungvittayakon C.
dc.contributor.authorJaovisidha S.
dc.contributor.authorChanplakorn P.
dc.contributor.otherMahidol University
dc.date.accessioned2023-06-18T17:48:25Z
dc.date.available2023-06-18T17:48:25Z
dc.date.issued2022-07-01
dc.description.abstractBackground: Periprosthetic femoral fracture (PFF) is well-known complication in cementless hip arthroplasty (HA), especially in the elderly with osteoporosis. To prevent intraoperative PFFs during HA, prophylactic cerclage wiring on the calcar area during femoral broaching and implant insertion is recommended. However, biomechanical data on the benefits of cerclage wiring in osteoporotic bone during impaction are limited and controversial. This study aimed to assess the efficacy of prophylactic double-looped cerclage wiring (PDLCW) during femoral broaching in the osteoporotic bone model with an impaction simulation system. Methods: Fifteen osteoporotic femur models were prepared and allocated to three groups; control group (no cerclage), PW group (received PDLCW), and CC+PW group (prepared as having calcar crack and received PDLCW). All femurs were broached under impaction force that sequentially increased until the visible fracture or calcar crack propagation was visible. The primary outcomes were mallet impaction force (MIF-CF) and mallet velocity (MV-CF) at the time of calcar fracture. The secondary outcomes were calcar fracture pattern and subsidence during calcar fracture (S-CF). Results: PW group showed a significant increase in average MIF-CF, by 40.4% and 120.2% (p<0.001) compared to the control and CC+PW groups, respectively. The average MV-CF in PW group was also significantly greater, 13.1% and 64.6% (p<0.001), compared to the control and CC+PW groups, respectively. Control group revealed significantly greater incidence of complete calcar fracture (60% vs. 0% vs. 0%, p = 0.024), and the highest S-CF compared to those in the PW and CC+PW groups (10.6 ± 6.0 mm, 6.7 ± 4.4 mm, and 1.3 ± 2.0 mm, p = 0.020). Conclusions: This study showed that PDLCW significantly improved hoop stress resistance by increasing the calcar fracture threshold related to mallet impaction, decreasing the risk of complete calcar fracture.
dc.identifier.citationInjury Vol.53 No.7 (2022) , 2454-2461
dc.identifier.doi10.1016/j.injury.2022.05.034
dc.identifier.eissn18790267
dc.identifier.issn00201383
dc.identifier.pmid35660012
dc.identifier.scopus2-s2.0-85131397792
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/85765
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleEffectiveness of prophylactic double-looped wiring in cementless Hip arthroplasty: A biomechanical study in osteoporotic bone model using impaction simulation system
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85131397792&origin=inward
oaire.citation.endPage2461
oaire.citation.issue7
oaire.citation.startPage2454
oaire.citation.titleInjury
oaire.citation.volume53