Modified high-flow nasal cannula for children with respiratory distress
8
item.page.dc.date.issued
2022-03-01
item.page.dc.type
item.page.dc.identifier.eissn
27134148
item.page.dc.identifier.doi
item.page.dc.identifier.scopus
2-s2.0-85127196817
item.page.oaire.citation.title
Clinical and Experimental Pediatrics
item.page.oaire.citation.volume
65
item.page.oaire.citation.issue
3
item.page.oaire.citation.startPage
136
item.page.oaire.citation.endPage
141
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Clinical and Experimental Pediatrics Vol.65 No.3 (2022) , 136-141
punsarn.item.page.citation
Itdhiamornkulchai S., Preutthipan A., Vaewpanich J., Anantasit N. Modified high-flow nasal cannula for children with respiratory distress. Clinical and Experimental Pediatrics Vol.65 No.3 (2022) , 136-141. 141. doi:10.3345/cep.2020.01403 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/86805
item.page.dc.title
Modified high-flow nasal cannula for children with respiratory distress
item.page.dc.contributor.author
item.page.oairecerif.author.affiliation
item.page.dc.contributor.other
item.page.dc.description.abstract
Background: High-flow nasal cannula (HFNC) is a noninva-sive respiratory support that provides the optimum flow of an air-oxygen mixture. Several studies demonstrated its usefulness and good safety profile for treating pediatric respiratory distress patients. However, the cost of the commercial HFNC is high; therefore, the modified high-flow nasal cannula was developed. Purpose: This study aimed to compare the effectiveness, safety, and nurses’ satisfaction of the modified system versus the standard commercial HFNC. Methods: This prospective comparative study was performed in a tertiary care hospital. We recruited children aged 1 month to 5 years who developed acute respiratory distress and were admitted to the pediatric intensive care unit. Patients were assigned to 2 groups (modified vs. commercial). The effectiveness and safety assessments included vital signs, respiratory scores, intubation rate, adverse events, and nurses’ satisfaction. Results: A total of 74 patients were treated with HFNC. Thirty-nine patients were assigned to the modified group, while the remaining 35 patients were in the commercial group. Intubation rate and adverse events did not differ significantly between the 2 groups. However, the commercial group had higher nurses’ satisfaction scores than the modified group. Conclusion: Our findings suggest that our low-cost modified HFNC could be a useful respiratory support option for younger children with acute respiratory distress, especially in hospital settings with financial constraints.
