Development and Validation of a New Design Self assessment logMAR Visual Acuity Test (“Chudjane” iPhone and iPad-based Application) in a Normal Eyes Population
dc.contributor.author | Rodanant N. | |
dc.contributor.author | Mahasith C. | |
dc.contributor.author | Thoongsuwan S. | |
dc.contributor.author | Phasukkijwatana N. | |
dc.contributor.author | Prakhunhungsit S. | |
dc.contributor.other | Mahidol University | |
dc.date.accessioned | 2023-06-18T17:44:27Z | |
dc.date.available | 2023-06-18T17:44:27Z | |
dc.date.issued | 2022-09-01 | |
dc.description.abstract | Objective: To validate and further design the “Chudjane” application (app), a new design self-assessment logMAR test for distance visual acuity (VA), by comparing the results against the use of a standard numeric ETDRS chart in normal eye population. Materials and Methods: In total, 52 volunteers who had a normal eye exam and best-corrected VA score by numeric ETDRS (NE) chart equal to or better than 6/6 (logMAR score 0.00 or less) were included. The “Chudjane” app with 3 patterns of optotypes (Arabic numbers (AN), Tumbling-E (TE) and Landolt-C (LC)) was used twice to assess VA individually. Results: The mean VA in each test NE, AN, TE, LC from the first round were -0.06, -0.10, -0.08 and -0.04, respectively compared to -0.07, -0.12, -0.09 and -0.05 from the second round respectively. Comparing results from the first and second round revealed that NE and LC had higher test-retest reliability (ICC=0.712, 0.789 respectively) than AN and TE (ICC=0.140, 0.495 respectively). For validity, result from NE was compared to each app test using the second round values. Modified Bland-Altman plot showed the mean differences (95% LOA) for NE-AN, NE-TE and NE-LC of 0.05 (-0.11 to 0.20), 0.02 (-0.11 to 0.15) and -0.03 (-0.19 to 0.13) respectively. Simple linear regression analysis of the difference (i.e. NE-AN, NE-TE and NE-LC) on NE showed that the difference did not depend on the NE value with slope close to zero. Conclusion: The study demonstrated that by using the «Chudjane» application, LC had higher test-retest reliability and higher validity than TE and AN compared to the standard ETDRS chart. | |
dc.identifier.citation | Siriraj Medical Journal Vol.74 No.9 (2022) , 590-599 | |
dc.identifier.doi | 10.33192/Smj.2022.70 | |
dc.identifier.eissn | 22288082 | |
dc.identifier.scopus | 2-s2.0-85137294518 | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/85568 | |
dc.rights.holder | SCOPUS | |
dc.subject | Medicine | |
dc.title | Development and Validation of a New Design Self assessment logMAR Visual Acuity Test (“Chudjane” iPhone and iPad-based Application) in a Normal Eyes Population | |
dc.type | Article | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85137294518&origin=inward | |
oaire.citation.endPage | 599 | |
oaire.citation.issue | 9 | |
oaire.citation.startPage | 590 | |
oaire.citation.title | Siriraj Medical Journal | |
oaire.citation.volume | 74 | |
oairecerif.author.affiliation | Siriraj Hospital |