Assessing Facial Palsy: Does Feedback Improve Assessment Using the eFACE and Sunnybrook Facial Grading System?

dc.contributor.authorBruins T.E.
dc.contributor.authorLammens R.F.
dc.contributor.authorvan Veen M.M.
dc.contributor.authorTamási K.
dc.contributor.authorDijkstra P.U.
dc.contributor.authorWerker P.M.N.
dc.contributor.authorBroekstra D.C.
dc.contributor.correspondenceBruins T.E.
dc.contributor.otherMahidol University
dc.date.accessioned2024-02-08T18:10:37Z
dc.date.available2024-02-08T18:10:37Z
dc.date.issued2024-01-01
dc.description.abstractObjective(s): To explore learning effects when applying the clinician-graded electronic facial function scale (eFACE) and the Sunnybrook Facial Grading System (Sunnybrook). Methods: Surgeons, facial rehabilitation therapists, and medical students were randomly allocated to the eFACE (n = 7) or Sunnybrook (n = 6) and graded 60 videos (Massachusetts Eye and Ear Infirmary open-source standard set); 10 persons with normal facial function and 50 patients with a wide variation of facial palsy severity. Participants received an introduction and individual feedback after each set of 10 videos. Scores were compared to the reference score provided with the set. Multilevel analysis was performed to analyze learning effect. Results: A learning effect was only found for the eFACE, with significant difference scores in set 1 and 2 compared to set 6, and no significant difference scores in the following sets. The difference score was associated with the reference score (severity of facial palsy) for eFACE (β = −0.19; SE = 0.04; p < 0.001) and Sunnybrook (β = −0.15; SE = 0.04; p < 0.001). Age of participants was also associated with the difference score in the eFACE group (β = 0.18; SE = 0.03; p < 0.001). No differences in scores were found between groups of participants. Conclusion: The eFACE showed a learning effect of feedback while the Sunnybrook did not. Level of Evidence: NA Laryngoscope, 2024.
dc.identifier.citationLaryngoscope (2024)
dc.identifier.doi10.1002/lary.31269
dc.identifier.eissn15314995
dc.identifier.issn0023852X
dc.identifier.pmid38217435
dc.identifier.scopus2-s2.0-85182465883
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/95665
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleAssessing Facial Palsy: Does Feedback Improve Assessment Using the eFACE and Sunnybrook Facial Grading System?
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85182465883&origin=inward
oaire.citation.titleLaryngoscope
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationUniversitair Medisch Centrum Groningen

Files

Collections