Effects of pulsation rate, surface overflow rate and suction height on the turbidity removal efficiency of pulsator clarifier
Issued Date
2005
Copyright Date
2005
Resource Type
Language
eng
File Type
application/pdf
No. of Pages/File Size
xii, 134 leaves : ill.
ISBN
9740460305
Access Rights
open access
Rights
ผลงานนี้เป็นลิขสิทธิ์ของมหาวิทยาลัยมหิดล ขอสงวนไว้สำหรับเพื่อการศึกษาเท่านั้น ต้องอ้างอิงแหล่งที่มา ห้ามดัดแปลงเนื้อหา และห้ามนำไปใช้เพื่อการค้า
Rights Holder(s)
Mahidol University
Bibliographic Citation
Thesis (M.Sc. (Environmental Technology))--Mahidol University, 2005
Suggested Citation
Surat Intrto Effects of pulsation rate, surface overflow rate and suction height on the turbidity removal efficiency of pulsator clarifier. Thesis (M.Sc. (Environmental Technology))--Mahidol University, 2005. Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/106070
Title
Effects of pulsation rate, surface overflow rate and suction height on the turbidity removal efficiency of pulsator clarifier
Alternative Title(s)
ผลของอัตราพัลเซชั่นอัตราน้ำล้นผิวและระยะยกของน้ำในห้องสุญญากาศต่อประสิทธิภาพการลดความขุ่นของถังตกตะกอนแบบพัลเซชั่นแคลริฟายเออร์
Author(s)
Abstract
The main objective of this research was to study the turbidity removal efficiency for raw water at Mahasawat water treatment plant by using pulsator clarifier model. A bench scale with a continuous operation was used to determine the optimum treatment by varying pulsation rate (6, 10 and 14 m/hr), surface overflow rate (2.90, 3.22 and 3.54 m/hr), and suction height (0.40, 0.60 and 0.80 m). Results indicated that the pulsation rate under these experimental ranges is not a directly important operating factor influencing the turbidity removal efficiency of the water treatment process. The surface overflow rates and suction heights are the important operating factors influencing turbidity removal efficiency. The study showed that when the surface overflow rates and the suction heights increased, the turbidity removal efficiency tended to decrease. The optimum turbidity removal conditions were at the pulsation rate of 14.00 m/hr, surface overflow rate of 3.22 m/hr and the suction height of 0.6 m. Under these conditions, the turbidity removal efficiency was 95.47 %. The turbidity of clarified water after treatment was 1.09 Nephelometric Turbidity Unit (NTU), which was lower than 5 Nephelometric Turbidity Unit (NTU) for normal plant operation condition.;"วัตถุประสงค์หลักของงานวิจัยนี้เพื่อศึกษาประสิทธิภาพการลดความขุ่นจากน้ำดิบที่โรงงานผลิตน้ำมหาสวัสดิ์โดยใช้แคลริฟายเออร์แบบพัลเซชั่นที่จำลองขึ้นซึ่งเป็นการศึกษาวิจัยเชิงทดลองแบบปฏิบัติการต่อเนื่องเพื่อหาสภาวะที่เหมาะสมในการลดความขุ่นโดยแปรค่าอัตราพัลเซชั่นเท่ากับ 6