CFD elucidation of high-pressure subcooled boiling flow towards effects of variable refrigerantproperties using OpenFOAM empirical closures

dc.contributor.authorMuangput B.
dc.contributor.authorZin T.
dc.contributor.authorNamchanthra S.
dc.contributor.authorPriyadumkol J.
dc.contributor.authorPhengpom T.
dc.contributor.authorChookaew W.
dc.contributor.authorSuvanjumrat C.
dc.contributor.authorPromtong M.
dc.contributor.correspondenceMuangput B.
dc.contributor.otherMahidol University
dc.date.accessioned2024-07-19T18:12:52Z
dc.date.available2024-07-19T18:12:52Z
dc.date.issued2024-09-01
dc.description.abstractBoiling flow presents a significant concern, especially when a liquid surpasses its boiling point, potentially leading to catastrophic consequences. This research utilizes a two-phase code in the OpenFOAM software to investigate bubble formation during flow boiling. The well-established empirical models for calculating wall heat components were selected based on the operating conditions. The study incorporates experimental data from high-pressure boiling flow (10–30 bars) with variable properties of refrigerant R-12. The predictions reveal underpredictions in void fraction and liquid temperature compared to experimental observations. Significantly, the impact of the subcooling degree on void fraction behaviour is emphasized, and a potential underprediction of the evaporation portion is highlighted, particularly near the wall. Challenges in modelling bubble size distribution are evident through discrepancies in bubble diameter and velocity data, indicating the necessity for further advancements in the code. In summary, this numerical study provides valuable insights into the intricate dynamics of high-pressure subcooled boiling flow, especially when considering variable working fluid properties. Future efforts will focus on refining models for nucleation site density, bubble departure size, and lift-off frequency to enhance prediction accuracy.
dc.identifier.citationApplications in Engineering Science Vol.19 (2024)
dc.identifier.doi10.1016/j.apples.2024.100187
dc.identifier.eissn26664968
dc.identifier.scopus2-s2.0-85198399926
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/99721
dc.rights.holderSCOPUS
dc.subjectEngineering
dc.titleCFD elucidation of high-pressure subcooled boiling flow towards effects of variable refrigerantproperties using OpenFOAM empirical closures
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85198399926&origin=inward
oaire.citation.titleApplications in Engineering Science
oaire.citation.volume19
oairecerif.author.affiliationMahidol University