Outcomes of Transcatheter Pulmonary Valve Replacement and Surgical Pulmonary Valve Replacement: A Cohort Analysis

dc.contributor.authorDurongpisitkul K.
dc.contributor.authorDangrungroj E.
dc.contributor.authorChungsomprasong P.
dc.contributor.authorVijarnsorn C.
dc.contributor.authorChanthong P.
dc.contributor.authorPacharapakornpong T.
dc.contributor.authorKanjanauthai S.
dc.contributor.authorSoongswang J.
dc.contributor.authorPanjasamanvong P.
dc.contributor.authorPlearntummakun P.
dc.contributor.authorTocharoenchok T.
dc.contributor.authorNitiyarom E.
dc.contributor.authorTantiwongkosri K.
dc.contributor.authorThongcharoen P.
dc.contributor.authorSubtaweesin T.
dc.contributor.authorSriyoschati S.
dc.contributor.otherMahidol University
dc.date.accessioned2023-06-26T17:57:01Z
dc.date.available2023-06-26T17:57:01Z
dc.date.issued2022-09-01
dc.description.abstractBackground: Transcatheter pulmonary valve replacement (TPVR) has become an alternative to surgical pulmonary valve placement (SPVR) for patients after tetralogy of Fallot repair. This study compared the outcomes of TPVR with those of SPVR. Methods: We reviewed data from patients who underwent pulmonary valve replacement with a median of 2 years of follow-up. Results: Between 2010 and 2021, 215 patients underwent pulmonary valve replacement (72 TPVR and 143 SPVR). The median size of the right ventricular end-diastolic volume index in the TPVR group was 165 mL/m2 (IQR, 136-190) and 184 mL/m2 (IQR, 163-230) in the SPVR group (P =.001). The median value of the maximum landing zone at the right ventricular outflow tract (RVOT) in patients with native RVOT was 26 mm (IQR, 24-28) in the 43 patients in the TPVR group and 31 mm (IQR, 28-34) in the 101 patients in the SPVR group (P <.001). The median size of the pulmonary valve implant for the native RVOT in the TPVR group was 29.0 mm (IQR, 26.0-29.0) and 24.0 mm (IQR, 24.0-24.0) in the SPVR group (P <.001). There were no deaths in the TPVR group and 8 deaths in the SPVR group (P =.041). Major complications and the length of hospitalization were lower in the TPVR group (P =.001). After 2 years, the mean decrease in QRS duration was 5 milliseconds (IQR, 1-14) in the TPVR group and 1 millisecond (IQR, −4 to 10) in the SPVR group (P =.006). Conclusions: TPVR allows for larger implants, resulting in lower mortality, shorter hospital stays, and fewer major cardiac events. SPVR may be preferable in patients with larger (>30 mm) native RVOT and in those who require concomitant surgical procedures.
dc.identifier.citationJournal of the Society for Cardiovascular Angiography and Interventions Vol.1 No.5 (2022)
dc.identifier.doi10.1016/j.jscai.2022.100408
dc.identifier.eissn27729303
dc.identifier.scopus2-s2.0-85161562698
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/87633
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleOutcomes of Transcatheter Pulmonary Valve Replacement and Surgical Pulmonary Valve Replacement: A Cohort Analysis
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85161562698&origin=inward
oaire.citation.issue5
oaire.citation.titleJournal of the Society for Cardiovascular Angiography and Interventions
oaire.citation.volume1
oairecerif.author.affiliationSiriraj Piyamaharajkarun Hospital
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationLerdsin Hospital
oairecerif.author.affiliationFaculty of Medicine Siriraj Hospital, Mahidol University

Files

Collections