Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening
| dc.contributor.author | Boriboonhirunsarn D. | |
| dc.contributor.author | Robkhonburi A. | |
| dc.contributor.author | Asad-dehghan M. | |
| dc.contributor.other | Mahidol University | |
| dc.date.accessioned | 2023-06-18T17:48:44Z | |
| dc.date.available | 2023-06-18T17:48:44Z | |
| dc.date.issued | 2022-07-01 | |
| dc.description.abstract | Purpose: To assess the accuracy of capillary blood glucose (CBG) compared to conventional venous plasma glucose (VPG) testing for 50-g glucose challenge test (GCT) in gestational diabetes (GDM) screening. Methods: A total of 300 women were enrolled and 50-g GCT for GDM screening was offered. At 1 h after glucose loading, CBG was evaluated by CONTOUR® PLUS glucose meter by well-trained nurses immediately after venipuncture for VPG. Results of CBG were compared with those from VPG to evaluate its accuracy. Women with venous plasma glucose > 140 mg/dL were offered 100-g OGTT for GDM diagnosis. Results: The mean age was 30.2 years and the mean gestational age at testing was 21.8 weeks. GDM was diagnosed in 34 women (11.3%). The mean VPG was 142.1 ± 32.9 mg/dL and the mean CBG was 129.3 ± 33.5 mg/dL. Mean difference was −12.3 ± 12.5 mg/dL, corresponding to −8.8 ± 11.4%. CBG significantly correlated with VPG with correlation coefficient of 0.929, p < 0.001. In the detection of abnormal 50-g GCT results (VPG ≥ 140 mg/dL), at 126 mg/dL cutoff, CBG had sensitivity of 92.5%, specificity of 81.8%, and positive and negative predictive values of 82.8%and 92%. None of the GDM would have been missed if CBG was used. Conclusion: CBG by a certified glucose meter could be considered as an alternative to conventional VPG testing for 50-g GCT for GDM screening using 126 mg/dL cutoff value. | |
| dc.identifier.citation | Diabetology International Vol.13 No.3 (2022) , 561-565 | |
| dc.identifier.doi | 10.1007/s13340-022-00572-3 | |
| dc.identifier.eissn | 21901686 | |
| dc.identifier.issn | 21901678 | |
| dc.identifier.scopus | 2-s2.0-85124255153 | |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/85780 | |
| dc.rights.holder | SCOPUS | |
| dc.subject | Medicine | |
| dc.title | Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening | |
| dc.type | Article | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85124255153&origin=inward | |
| oaire.citation.endPage | 565 | |
| oaire.citation.issue | 3 | |
| oaire.citation.startPage | 561 | |
| oaire.citation.title | Diabetology International | |
| oaire.citation.volume | 13 | |
| oairecerif.author.affiliation | Siriraj Hospital |
