Increasing Dialysate Flow Rate over 500 ml/min for Reused High-Flux Dialyzers do not Increase Delivered Dialysis Dose: A Prospective Randomized Cross Over Study
dc.contributor.author | Srisuwan W. | |
dc.contributor.other | Mahidol University | |
dc.date.accessioned | 2023-06-20T05:33:50Z | |
dc.date.available | 2023-06-20T05:33:50Z | |
dc.date.issued | 2022-03-01 | |
dc.description.abstract | Objective: The primary objectives were: 1) to study the impact of Qd (500 vs 800 ml/min) on the delivered dose by reused dialyzers, and 2) to determine dialysis efficiency of a dialyzer reused 15 times. Materials and Methods: A prospective randomized-controlled crossover study was conducted in 42 thrice-weekly hemodialysis (HD) patients (630 HD sessions in each Qd). Delivered doses at both Qds were assessed by single-pool Kt/V (spKt/V), equilibrated Kt/V (eKt/V) and online clearance monitoring Kt/V (Kt/VOCM), measured at mid-week HD session using a new dialyzer and then again at every mid-week HD session. Results: Although the spKt/V in HD sessions using new dialyzers at Qd of 500 ml/min was slightly lower than spKt/V at Qd of 800 ml/min (2.19±0.08 vs. 2.34±0.08, respectively, P=0.04), when accounting for urea rebound as assessed by eKt/V and Kt/VOCM, there was no significant difference. The average delivered doses in dialyzers reused 15 times, with the mean average of spKt/V, eKt/V and Kt/VOCM at Qd 500 ml/min, were not significantly inferior to the delivered doses at Qd 800 ml/min. Reusing a dialyzer 15 times did not decrease dialysis efficiency and delivered doses in all HD sessions reached spKt/V >1.4. Conclusion: Increasing Qd over 500 ml/min for modern dialyzers does not significantly increase delivered dose of dialysis. Dialyzer reuse does not affect dialysis efficiency and provides adequate dialysis therapy | |
dc.identifier.citation | Siriraj Medical Journal Vol.74 No.3 (2022) , 152-160 | |
dc.identifier.doi | 10.33192/Smj.2022.19 | |
dc.identifier.eissn | 22288082 | |
dc.identifier.scopus | 2-s2.0-85126098417 | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/87359 | |
dc.rights.holder | SCOPUS | |
dc.subject | Medicine | |
dc.title | Increasing Dialysate Flow Rate over 500 ml/min for Reused High-Flux Dialyzers do not Increase Delivered Dialysis Dose: A Prospective Randomized Cross Over Study | |
dc.type | Article | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85126098417&origin=inward | |
oaire.citation.endPage | 160 | |
oaire.citation.issue | 3 | |
oaire.citation.startPage | 152 | |
oaire.citation.title | Siriraj Medical Journal | |
oaire.citation.volume | 74 | |
oairecerif.author.affiliation | Siriraj Hospital |