Flow dependence of handheld breath analyzer for body fuel utilization monitoring

dc.contributor.authorSricharoen C.
dc.contributor.authorWaritananta T.
dc.contributor.authorWattanavicheana N.
dc.contributor.authorJaisuthi R.
dc.contributor.authorOsotchan T.
dc.contributor.otherMahidol University
dc.date.accessioned2023-05-19T07:55:11Z
dc.date.available2023-05-19T07:55:11Z
dc.date.issued2023-01-01
dc.description.abstractHome healthcare medical technologies have been gaining popularity and are more affordable in recent years. Exhaled breath analysis has potential in this field. The development of gas sensor technology has enabled us to build a small affable breath analysis device with the electronic nose concept. In this work, a handheld breath analyzer was developed for monitoring body fuel utilization. A hybrid gas sensor array, including electrochemical and photoacoustic gas sensors, was used to accurately measure oxygen and carbon dioxide in exhaled breath. The bypass configuration volume flow measurement method was developed to fit a small portable device. The experiment shows that both oxygen and carbon dioxide sensors are flow-dependent due to the slow response time of each sensor type. The response of the photoacoustic sensor is relatively slower than those of other sensor types. Thus, a mathematical model was developed to correct the individual sensor value to get a more accurate value of body fuel utilization. The comparison protocol of known concentrations of the oxygen and carbon gases with various flow conditions was conducted, and the mathematical model for reconstructing the original gas concentration was proposed. The result shows that the device is able to detect the RER change of humans after having a high carbohydrate content meal and after exercise
dc.identifier.citationJournal of Physics: Conference Series Vol.2431 No.1 (2023)
dc.identifier.doi10.1088/1742-6596/2431/1/012017
dc.identifier.eissn17426596
dc.identifier.issn17426588
dc.identifier.scopus2-s2.0-85148029597
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/82250
dc.rights.holderSCOPUS
dc.subjectPhysics and Astronomy
dc.titleFlow dependence of handheld breath analyzer for body fuel utilization monitoring
dc.typeConference Paper
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85148029597&origin=inward
oaire.citation.issue1
oaire.citation.titleJournal of Physics: Conference Series
oaire.citation.volume2431
oairecerif.author.affiliationMahidol University
oairecerif.author.affiliationThammasat University

Files

Collections