Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis
dc.contributor.author | Somboonsuk T. | |
dc.contributor.author | Saetear P. | |
dc.contributor.author | Mantim T. | |
dc.contributor.author | Ratanawimarnwong N. | |
dc.contributor.author | Wilairat P. | |
dc.contributor.author | Choengchan N. | |
dc.contributor.author | Nacapricha D. | |
dc.contributor.other | Mahidol University | |
dc.date.accessioned | 2023-05-19T07:35:56Z | |
dc.date.available | 2023-05-19T07:35:56Z | |
dc.date.issued | 2023-02-01 | |
dc.description.abstract | This work presents the use of a transparent ‘Cross Injection Analysis’ (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H2O2-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)63− on the H2O2-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L−1 Co(II) (r2 = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L−1 (r2 = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h−1. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle. | |
dc.identifier.citation | Molecules Vol.28 No.3 (2023) | |
dc.identifier.doi | 10.3390/molecules28031316 | |
dc.identifier.eissn | 14203049 | |
dc.identifier.pmid | 36770983 | |
dc.identifier.scopus | 2-s2.0-85147895656 | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/81662 | |
dc.rights.holder | SCOPUS | |
dc.subject | Biochemistry, Genetics and Molecular Biology | |
dc.title | Transparent Cross-Flow Platform as Chemiluminescence Detection Cell in Cross Injection Analysis | |
dc.type | Article | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85147895656&origin=inward | |
oaire.citation.issue | 3 | |
oaire.citation.title | Molecules | |
oaire.citation.volume | 28 | |
oairecerif.author.affiliation | King Mongkut's Institute of Technology Ladkrabang | |
oairecerif.author.affiliation | Mahidol University | |
oairecerif.author.affiliation | Srinakharinwirot University | |
oairecerif.author.affiliation | Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs) |