Reliability of capillary refill time for evaluation of tissue perfusion in simulated vascular occluded limbs

dc.contributor.authorMonteerarat Y.
dc.contributor.otherMahidol University
dc.date.accessioned2023-06-18T17:53:30Z
dc.date.available2023-06-18T17:53:30Z
dc.date.issued2022-04-01
dc.description.abstractPurpose: No standardized execution or evidence demonstrates the area of the digit giving the most accurate capillary refill time (CRT). This study investigated the reliability and validity of CRT, and the relative merits of areas where the test could be performed. Methods: In all, 127 healthy volunteers were assessed for normal CRT at the fingernail, lateral paronychia, and proximal and distal pulps of the index finger. The predictive validity of the CRT for the diagnosis of compromised vascular perfusion was also investigated on 24 subjects, using an inflated tourniquet. Three raters assessed interobserver reliability. Results: The mean fingernail, lateral paronychia, proximal pulp, and distal pulp CRTs were 1.93, 1.78, 1.70, and 1.57 s, respectively. The tourniquet and non-tourniquet results demonstrated significant mean differences; however, the fingernail showed a subtle difference (1.22 s) compared with the proximal pulp (4.46 s). The CRT interobserver reliability was fair at the fingernail (intraclass correlation coefficient [ICC] = 0.51), but very poor in occluded limbs (ICC = 0.13). At the lateral paronychia and finger pulp, the interobserver reliability was reasonable (ICC = 0.75–0.81 [non-tourniquet] vs 0.62–0.68 [tourniquet]). In a receiver-operating characteristic curve analysis, the proximal pulp demonstrated better discrimination (area under the curve = 0.93, 95% CI 0.89–0.97, p < 0.0001); the best cutoff point was calculated to be 3 s at the proximal pulp. Conclusions: CRT use at appropriate areas is reliable. The most dependable site is the finger pulp, and the proposed cutoff is 3 s.
dc.identifier.citationEuropean Journal of Trauma and Emergency Surgery Vol.48 No.2 (2022) , 1231-1237
dc.identifier.doi10.1007/s00068-020-01594-9
dc.identifier.eissn16153146
dc.identifier.issn18639933
dc.identifier.pmid33475776
dc.identifier.scopus2-s2.0-85099773454
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/86021
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.titleReliability of capillary refill time for evaluation of tissue perfusion in simulated vascular occluded limbs
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85099773454&origin=inward
oaire.citation.endPage1237
oaire.citation.issue2
oaire.citation.startPage1231
oaire.citation.titleEuropean Journal of Trauma and Emergency Surgery
oaire.citation.volume48
oairecerif.author.affiliationSiriraj Hospital

Files

Collections