10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure.
| dc.contributor.author | Lohasammakul S. | |
| dc.contributor.author | D’John J. | |
| dc.contributor.author | Qasawa R. | |
| dc.contributor.author | Llewellyn K.J. | |
| dc.contributor.author | Moltaji S. | |
| dc.contributor.author | Fuse Y. | |
| dc.contributor.author | Chaiyasate K. | |
| dc.contributor.correspondence | Lohasammakul S. | |
| dc.contributor.other | Mahidol University | |
| dc.date.accessioned | 2026-04-18T18:24:25Z | |
| dc.date.available | 2026-04-18T18:24:25Z | |
| dc.date.issued | 2026-03-13 | |
| dc.description.abstract | Background: – The combination of deep inferior epigastric artery perforator (DIEP) free flap and implant has been reported as a safe option for breast reconstruction in patients with insufficient abdominal donor tissue. We present a single-surgeon 10-year experience with hybrid reconstruction. Methods: – We performed a retrospective review of patients who underwent hybrid breast reconstruction with DIEP and implant by a single surgeon at a single institution between 2014-2024. Patient characteristics and operative factors were analyzed for association with flap failure. Results: – 91 patients (153 breasts) were included. Success rate following initial (simultaneous or delayed) implantation and after implant exchange were 98% and 96.1%, respectively. Univariate analyses showed significantly larger mean final implant size in the failed DIEP group (362.50±228.05 mL) compared to the successful reconstruction group (219.20±101.24 mL), with OR of 1.42 (95% CI: 1.149–1.76, p-value = 0.002) per 50 mL increase of the implant size. Conclusions: – Hybrid DIEP with implant reconstruction is a safe procedure. Placement of a greater volume implant is associated with flap failure. Implant exchange for upsize also possesses a risk of flap failure. | |
| dc.identifier.citation | Plastic and Reconstructive Surgery Vol.Publish Ahead of Print (2026) | |
| dc.identifier.doi | 10.1097/PRS.0000000000013029 | |
| dc.identifier.eissn | 15294242 | |
| dc.identifier.issn | 00321052 | |
| dc.identifier.scopus | 2-s2.0-105035511386 | |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/116253 | |
| dc.rights.holder | SCOPUS | |
| dc.subject | Medicine | |
| dc.title | 10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure. | |
| dc.type | Article | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105035511386&origin=inward | |
| oaire.citation.title | Plastic and Reconstructive Surgery | |
| oaire.citation.volume | Publish Ahead of Print | |
| oairecerif.author.affiliation | Siriraj Hospital | |
| oairecerif.author.affiliation | Corewell Health William Beaumont University Hospital | |
| oairecerif.author.affiliation | Corewell Health Farmington Hills |
