10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure.

dc.contributor.authorLohasammakul S.
dc.contributor.authorD’John J.
dc.contributor.authorQasawa R.
dc.contributor.authorLlewellyn K.J.
dc.contributor.authorMoltaji S.
dc.contributor.authorFuse Y.
dc.contributor.authorChaiyasate K.
dc.contributor.correspondenceLohasammakul S.
dc.contributor.otherMahidol University
dc.date.accessioned2026-04-18T18:24:25Z
dc.date.available2026-04-18T18:24:25Z
dc.date.issued2026-03-13
dc.description.abstractBackground: – The combination of deep inferior epigastric artery perforator (DIEP) free flap and implant has been reported as a safe option for breast reconstruction in patients with insufficient abdominal donor tissue. We present a single-surgeon 10-year experience with hybrid reconstruction. Methods: – We performed a retrospective review of patients who underwent hybrid breast reconstruction with DIEP and implant by a single surgeon at a single institution between 2014-2024. Patient characteristics and operative factors were analyzed for association with flap failure. Results: – 91 patients (153 breasts) were included. Success rate following initial (simultaneous or delayed) implantation and after implant exchange were 98% and 96.1%, respectively. Univariate analyses showed significantly larger mean final implant size in the failed DIEP group (362.50±228.05 mL) compared to the successful reconstruction group (219.20±101.24 mL), with OR of 1.42 (95% CI: 1.149–1.76, p-value = 0.002) per 50 mL increase of the implant size. Conclusions: – Hybrid DIEP with implant reconstruction is a safe procedure. Placement of a greater volume implant is associated with flap failure. Implant exchange for upsize also possesses a risk of flap failure.
dc.identifier.citationPlastic and Reconstructive Surgery Vol.Publish Ahead of Print (2026)
dc.identifier.doi10.1097/PRS.0000000000013029
dc.identifier.eissn15294242
dc.identifier.issn00321052
dc.identifier.scopus2-s2.0-105035511386
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/116253
dc.rights.holderSCOPUS
dc.subjectMedicine
dc.title10-Year Experience of Hybrid DIEP with Implant Breast Reconstruction: Univariate Analyses of Risk Factors Associated with Flap Failure.
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105035511386&origin=inward
oaire.citation.titlePlastic and Reconstructive Surgery
oaire.citation.volumePublish Ahead of Print
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationCorewell Health William Beaumont University Hospital
oairecerif.author.affiliationCorewell Health Farmington Hills

Files

Collections