dc.description.abstractBACKGROUND: Visual read of Aβ PET remains standard clinical practice. 18F-NAV4694 (NAV) has high affinity for Aβ and low non-specific binding so may be more accurate than older Aβ tracers. We compared visual read of NAV to 18F-Florbetapir (FBP) PET using standard and AI corrected Centiloid (CL) thresholds as gold standard. METHOD: 150 participants (71.3±6.0 years) in the AIBL study underwent both scans within 2 years. Scans were read by 6 nuclear medicine physicians blinded to CL. Reader performance was compared against various CL thresholds. CL was measured with CapAIBL using a) the standard method, b) a composite cerebellum plus hemispheric white matter reference region for FBP and c) with an AI correction method for the CL SUVR (DeepSUVR). The DeepSUVR correction was learnt from a separate dataset of longitudinal scans where unexpected temporal changes were penalized and a tracer specific SUVR correction factor was developed for application to single scans. RESULT: CL frequency distribution graphs differed for NAV and FBP. Applying the DeepSUVR correction improved the correlation (R2) between NAV and FBP CL from 0.82 to 0.94, predominantly by boosting many mid-range FBP CL values and reducing FBP variance around zero CL (Figure 1). The FBP composite reference region had a similar though less marked effect. The thresholds that produced peak visual read accuracy with standard and DeepSUVR CL methods were 15CL and 11CL for NAV, and 29CL and 21CL for FBP (Figure 2). Mean sensitivity at peak accuracy thresholds was higher in NAV with 97% for standard and 96% for DeepSUVR methods compared to 93% for both methods in FBP. Mean specificity at the same thresholds was similar with 95% for NAV and FBP with standard CL while DeepSUVR produced a specificity of 97% for both tracers. CONCLUSION: Visual read of amyloid PET can accurately detect levels of amyloid below the traditional thresholds of 20 or 25CL for a positive scan. Visual read thresholds vary by tracer and reader experience. AI correction of CL with the DeepSUVR method significantly improves the performance of Florbetapir but NAV4694 remains more sensitive to low amyloid levels.
dc.identifier.citationAlzheimer S Dementia the Journal of the Alzheimer S Association Vol.21 (2025) , e110277
dc.identifier.doi10.1002/alz70862_110277
dc.identifier.eissn15525279
dc.identifier.pmid41434227
dc.identifier.scopus2-s2.0-105025735903
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/113716
dc.rights.holderSCOPUS
dc.subjectNeuroscience
dc.subjectMedicine
dc.titleAlzheimer's Imaging Consortium
dc.typeArticle
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105025735903&origin=inward
oaire.citation.titleAlzheimer S Dementia the Journal of the Alzheimer S Association
oaire.citation.volume21
oairecerif.author.affiliationUniversity of Melbourne
oairecerif.author.affiliationCommonwealth Scientific and Industrial Research Organisation
oairecerif.author.affiliationUniversity of Pittsburgh School of Medicine
oairecerif.author.affiliationRoyal Melbourne Hospital
oairecerif.author.affiliationSiriraj Hospital
oairecerif.author.affiliationAustin Health
oairecerif.author.affiliationThe Florey
oairecerif.author.affiliationFaculty of Medicine, Chiang Mai University

Files

Collections