Determination of cystatin C using paper-based analytical devices for early detection of renal failure

dc.contributor.authorSabarudin A.
dc.contributor.authorTyas A.A.
dc.contributor.authorPamungkas B.D.
dc.contributor.authorPratama I.G.B.A.
dc.contributor.authorAndayani U.
dc.contributor.authorSakti S.P.
dc.contributor.otherMahidol University
dc.date.accessioned2023-11-27T18:03:00Z
dc.date.available2023-11-27T18:03:00Z
dc.date.issued2023-08-21
dc.description.abstractRenal failure is often detected when it has reached the last stage. The amount of cystatin C in blood serum can be used as a biomarker for early identification of renal function failure. This work reported a fast and environmentally friendly microfluidic paper-based analytical device (μPAD) to determine the amount of cystatin C in the artificial blood serum samples. Functionalized gold nanoparticles (AuNPs) were prepared by capping the surface of AuNPs with papain to form AuNPs-papain. The aggregate of functionalized AuNPs-papain and Cu2+ ion could be formed due to coordination interaction between Cu2+ ion and papain attached to AuNPs. In the presence of cystatin C, the amount of aggregate decreased because the functionalized AuNPs-papain would bind easily with cystatin C as the substrate of papain. The intensity of aggregate on μPAD was scanned using a paper scanner. The difference intensity of aggregate in the presence of cystatin C was proportional to the concentration of cystatin C in the artificial blood serum sample. The linearity range obtained by this work was 0.5-10.0?mg/L with regression of y=0.3302x+3.488 and linearity of r2=0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.511 (3xSD/slope) and 2.044?mg/L (12xSD/slope), respectively. The linearity range and the LOD were wide enough to detect cystatin C in normal people or people with renal diseases.
dc.identifier.citationAIP Conference Proceedings Vol.2818 No.1 (2023)
dc.identifier.doi10.1063/5.0131190
dc.identifier.eissn15517616
dc.identifier.issn0094243X
dc.identifier.scopus2-s2.0-85176953660
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/91213
dc.rights.holderSCOPUS
dc.subjectPhysics and Astronomy
dc.titleDetermination of cystatin C using paper-based analytical devices for early detection of renal failure
dc.typeConference Paper
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85176953660&origin=inward
oaire.citation.issue1
oaire.citation.titleAIP Conference Proceedings
oaire.citation.volume2818
oairecerif.author.affiliationBrawijaya University
oairecerif.author.affiliationMahidol University