Search Results

Now showing 1 - 9 of 9
  • Thumbnail Image
    PublicationOpen Access
    The potential of copper alloy as alternative material for post and core applications.
    (2014-09) Somchai Urapepon; สมชาย อุรพีพล; Usanee Peungpaiboon; อุษณีย์ ปึงไพบูลย์; Somchai Urapepon; สมชาย อุรพีพล; Mahidol University. Faculty of Dentistry. Department of Prosthodontics
    Objective: The purpose of this study was to investigate the use of copper alloy for dental application. Materials and methods: Three types of copper alloy used in Thailand were selected (Cu-Al, Cu-Al-Ni and Cu-Zn). Ingots of these three alloys... were prepared. The tensile test and potentiodynamic polarization for corrosion test were performed following ISO 1562: 2004 Dentistry-Casting gold alloys and ISO 10271: 2001 Dental metallic materials-Corrosion test method. The ultimate strength, 0
  • Publication
    Properties of experimental copper-aluminiumnickel alloys for dental post-and-core applications
    (2014-01-01) Apiwat Rittapai; Somchai Urapepon; Julathep Kajornchaiyakul; Choltacha Harniratisai; Mahidol University; National Metal and Materials Technology Center (MTEC)
    PURPOSE: This study aimed to develop a copper-aluminium-nickel alloy which has properties comparable to that of dental alloys used for dental post and core applications with the reasonable cost. MATERIALS AND METHODS: Sixteen groups of experimental... copper alloys with variants of 3, 6, 9, 12 wt% Al and 0, 2, 4, 6 wt% Ni were prepared and casted. Their properties were tested and evaluated. The data of thermal, physical, and mechanical properties were analyzed using the two-way ANOVA and Tukey's test
  • Publication
    The influence of copper in dealloyed binary platinum-copper electrocatalysts on methanol electroxidation catalytic activities
    (2015-01-01) Chatwarin Poochai; Waret Veerasai; Ekasith Somsook; Somsak Dangtip; Mahidol University
    and selective copper dealloying in an acidic medium, and we investigated the effect of the copper content in the samples on the catalytic activities toward methanol electroxidation reaction (MOR). X-ray photo-emission spectroscopy (XPS) and inductively coupled... were zero and one, respectively, implying the formation of metallic Pt and Cu2O, respectively. X-ray diffraction spectroscopy (XRD) confirmed that Cu was inserted into a face-centered cubic Pt structure forming Pt-Cu alloys. Scanning electron
  • Publication
    Composition and transitional temperature range of several nickel-titanium alloy wires in orthodontic treatment
    (2011-09-23) Rutchadakorn Isarapatanapong; Surachai Dechkunakorn; Niwat Anuwongnukroh; Nattiree Chiranavanit; Julathep Kajorchaiyakul; Anak Khantachawana; Mahidol University; Thailand National Metal and Materials Technology Center; King Mongkuts University of Technology Thonburi
    . The wires were tested in differential scanning calorimetry to find the transitional temperature range. Results: The compositions were nickel (50.085%-51.605%), titanium (46.675%-48.140%), copper (0.995%-1.155%), aluminum (0.220%-1.325%), chromium (0%-0
  • Publication
    Loading and unloading forces following addition of 5% Cu in nickel-titanium alloy used for orthodontics
    (2017-01-01) Aphinan Phukaoluan; Surachai Dechkunakorn; Niwat Anuwongnukroh; Anak Khantachawana; Pongpan Kaewtathip; Julathep Kajornchaiyakul; Wassana Wichai; King Mongkut s University of Technology Thonburi; Mahidol University; Thailand National Metal and Materials Technology Center
    orthodontic archwire. Nickel (purity 99.9%), Titanium (purity 99.8%), and Copper (purity 99.9%) were used in this study with the atomic weight ratio 46.0 Ni: 49.0 Ti: 5.0 Cu. The elements were melted to form an alloy using an electrolytic arc furnace in argon... gas atmosphere and homogenized at 800°C for 1 hr. The alloys were subsequently sliced into thin plates (1.5mm) by EDM wire cutting machine to obtain the specimens and were cold-rolled with 30% reduction followed by heat treatment in a furnace at 400°C
  • Publication
    Comparison of friction forces between stainless orthodontic steel brackets and TiNi wires in wet and dry conditions
    (2017-03-01) Aphinan Phukaoluan; Anak Khantachawana; Pongpan Kaewtatip; Surachai Dechkunakorn; Niwat Anuwongnukroh; Peerapong Santiwong; Julathep Kajornchaiyakul; King Mongkut s University of Technology Thonburi; Mahidol University; Thailand National Metal and Materials Technology Center
    the frictional forces between a stainless steel bracket and five different wire alloys under dry and wet (artificial saliva) conditions. TiNi, TiNiCu, TiNiCo, commercial wires A and commercial wires B with equal dimensions of 0.016 × 0.022′′ were tested... roughness testing. Static and kinetic friction forces were measured using a custom-designed apparatus, with a 3-mm stretch of wire alloy at a crosshead speed of 1 mm/min. The static and dynamic frictions in the wet condition tended to decrease more slowly
  • Thumbnail Image
    PublicationOpen Access
    Surface hardness of Thai spherical amalgam product.
    (2015-01) Pornkiat Churnjitapirom; พรเกียรติ ชื่นจิตอภิรมย์; Chayada Teanchai; ชญาดา เทียนไชย; Anucha Sacharoen; อนุชา ซาเจริญ; Anucha Sacharoen; อนุชา ซาเจริญ; Mahidol University. Faculty of Dentistry. Research Office
    Objective: The purpose of this study was to compare the surface hardness of Thai spherical amalgam product (N’SURE) with three commercial spherical amalgams (Tytin FC®, Amalcap® Plus, and GS-80 spherical). Materials and methods: Ten specimens were prepared from each of four spherical amalgams and then stored at 37°C for 24 hours. The surface of each specimen was polished using SiC paper (P240 to P4,000) and finished using alumina particles (average particle size, 0.05 µm). Surface hardness was then measured using Vickers hardness test under 1 kgf load for 15 seconds. The data were statistically analyzed using One-way ANOVA and Tukey’s multiple comparison test at 95% confidence interval. Results: The surface hardness of all spherical amalgams ranged from 127.77 to 158.51 HV1. Significant differences in surface hardness were found among all spherical amalgams. The highest was GS-80 spherical followed by Tytin FC®, Thai amalgam, and the lowest was Amalcap® Plus. Conclusion: The result of this study showed that surface hardness of Thai spherical amalgam product is comparable to commercially available spherical amalgams.
  • Publication
    Effect of direct electric resistance heat treatment on loading/unloading behavior of nickel titanium orthodontic wire
    (2014-01-27) Surachai Dechkunakorn; Chavarit Sujaritviriyakul; Niwat Anuwongnukroh; Nathaphon Tangit; Mahidol University
    Objective: The aim of this study was to investigate and compare the loading and unloading characteristics of various nickel-titanium (NiTi) and nickel-titanium-copper (NiTiCu) after direct electric resistance heat treatment method (Bender soarer-X... Sentalloy, Tomy L&H and Ormco NiTiCu had significantly different results (p<0.05) after heat treatments. The factors which could affect the loading and unloading characteristics were the difference in alloy composition and the condition of heat treatment
  • Thumbnail Image
    PublicationOpen Access
    ความขรุขระผิวของอะมัลกัมที่ผลิตในประเทศไทยภายหลังการขัดและการแปรง
    (2013-09) พรเกียรติ ชื่นจิตอภิรมย์; Pornkiat Churnjitapirom; ชญาดา เทียนไชย; Chayada Teanchai; อภิวัฒน์ ฤทธาภัย; Apiwat Rittapai; ชญาดา เทียนไชย; Chayada Teanchai; มหาวิทยาลัยมหิดล. คณะทันแพทยศาสตร์. สำนักงานการวิจัย
    วัตถุประสงค์: เพื่อศึกษาความขรุขระผิวของอะมัลกัมที่ผลิตในประเทศไทยภายหลังจาก การขัดและการแปรงเปรียบเทียบกับอะมัลกัมที่จำหน่ายในท้องตลาด 4 ชนิด คือ Tytin FC, Amalcap Plus, GS-80 spherical และ GS-80 วัสดุอุปกรณ์และวิธีการศึกษา: เตรียมชิ้นตัวอย่างอะมัลกัมในแม่แบบอะคริลิกชนิด ละ 20 ตัวอย่าง เก็บไว้ที่อุณหภูมิ 37 องศาเซลเซียส เป็นเวลา 24 ชั่วโมง จากนั้นนำชิ้น ตัวอย่างทั้งหมดมาขัดด้วยหัวขัดเรียงตามลำดับความหยาบไปจนถึงละเอียดคือ หัวขัด สโตนขาว หัวยางแดงขัดอะมัลกัม และหัวยางเขียวขัดอะมัลกัม นำตัวอย่างอะมัลกัมที่ขัด เสร็จชนิดละ 10 ตัวอย่าง ไปทดสอบความขรุขระผิว เหลือตัวอย่างขัดเสร็จอีกชนิดละ 10 ตัวอย่าง นำไปแปรงกับแปรงสีฟันและสารละลายยาสีฟันด้วยเครื่องแปรงฟัน จากนั้นนำ ไปทดสอบความขรุขระผิว นำค่าความขรุขระผิวมาวิเคราะห์ทางสถิติโดยใช้การวิเคราะห์ ความแปรปรวนทางเดียว และ Tukey’s test เปรียบเทียบพหุคูณที่ระดับนัยสำคัญ 0.05 ผลการศึกษา: ผลการศึกษาพบว่าภายหลังการขัดและการแปรง Tytin FC มีค่าความ ขรุขระผิวน้อยกว่าทุกชนิดอย่างมีนัยสำคัญที่ระดับ 0.05 และในทำนองเดียวกัน GS-80 มีค่าความขรุขระผิวมากกว่าทุกชนิดอย่างมีนัยสำคัญที่ระดับ 0.05 ขณะที่อะมัลกัมไทย, Amalcap Plus และ GS-80 spherical มีค่าความขรุขระผิวไม่ต่างกัน สำหรับการเปรียบ เทียบความขรุขระผิวระหว่างภายหลังการขัดกับการแปรงพบว่าอะมัลกัมทุกผลิตภัณฑ์ ยกเว้น GS-80 ผิวภายหลังการแปรงกับสารละลายยาสีฟันมีค่าความขรุขระมากกว่าการ ขัดอย่างมีนัยสำคัญที่ระดับ 0.05 และ GS-80 มีความขรุขระมากกว่าทุกผลิตภัณฑ์ใน ระดับเดิม บทสรุป: จากผลการตรวจสอบความขรุขระผิวของอะมัลกัมไทยกับอะมัลกัมที่จำหน่ายใน ท้องตลาด 4 ชนิด ภายหลังการขัดและการแปรงพบว่าอะมัลกัมไทยมีความขรุขระผิวใกล้ เคียงหรือน้อยกว่าอะมัลกัมที่จำหน่ายในท้องตลาดบางชนิด คาดว่าอะมัลกัมไทยสามารถ นำไปใช้ทางคลินิกได้อย่างมีประสิทธิภาพ