Publication: ICSH recommendations for assessing automated high-performance liquid chromatography and capillary electrophoresis equipment for the quantitation of HbA<inf>2</inf>
dc.contributor.author | A. D. Stephens | en_US |
dc.contributor.author | R. Colah | en_US |
dc.contributor.author | S. Fucharoen | en_US |
dc.contributor.author | J. Hoyer | en_US |
dc.contributor.author | D. Keren | en_US |
dc.contributor.author | A. Mcfarlane | en_US |
dc.contributor.author | D. Perrett | en_US |
dc.contributor.author | B. J. Wild | en_US |
dc.contributor.other | UCL | en_US |
dc.contributor.other | Institute of Immunohaematology Mumbai | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Mayo Clinic | en_US |
dc.contributor.other | University of Michigan, Ann Arbor | en_US |
dc.contributor.other | Institute for Quality Management in Healthcare (IQMH) | en_US |
dc.contributor.other | Barts and The London School of Medicine Charterhouse Square | en_US |
dc.contributor.other | Hammersmith Hospital | en_US |
dc.date.accessioned | 2018-11-23T09:51:46Z | |
dc.date.available | 2018-11-23T09:51:46Z | |
dc.date.issued | 2015-01-01 | en_US |
dc.description.abstract | © 2015 John Wiley & Sons Ltd. Automated high performance liquid chromatography and Capillary electrophoresis are used to quantitate the proportion of Hemoglobin A<inf>2</inf> (HbA<inf>2</inf>) in blood samples order to enable screening and diagnosis of carriers of β-thalassemia. Since there is only a very small difference in HbA<inf>2</inf> levels between people who are carriers and people who are not carriers such analyses need to be both precise and accurate. This paper examines the different parameters of such equipment and discusses how they should be assessed. | en_US |
dc.identifier.citation | International Journal of Laboratory Hematology. Vol.37, No.5 (2015), 577-582 | en_US |
dc.identifier.doi | 10.1111/ijlh.12413 | en_US |
dc.identifier.issn | 1751553X | en_US |
dc.identifier.issn | 17515521 | en_US |
dc.identifier.other | 2-s2.0-84941623803 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/35646 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84941623803&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | ICSH recommendations for assessing automated high-performance liquid chromatography and capillary electrophoresis equipment for the quantitation of HbA<inf>2</inf> | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84941623803&origin=inward | en_US |