Publication: Latticed gold nanoparticle conjugation via monomeric streptavidin in lateral flow assay for detection of autoantibody to interferon-gamma
dc.contributor.author | Weeraya Thongkum | en_US |
dc.contributor.author | Umpa Yasamut | en_US |
dc.contributor.author | Koollawat Chupradit | en_US |
dc.contributor.author | Supachai Sakkhachornphop | en_US |
dc.contributor.author | Jiraprapa Wipasa | en_US |
dc.contributor.author | Kanokporn Sornsuwan | en_US |
dc.contributor.author | On Anong Juntit | en_US |
dc.contributor.author | Rawiwan Pornprasit | en_US |
dc.contributor.author | Wanwisa Thongkamwitoon | en_US |
dc.contributor.author | Jirapan Chaichanan | en_US |
dc.contributor.author | Jaruwan Khaoplab | en_US |
dc.contributor.author | Chonnikarn Chanpradab | en_US |
dc.contributor.author | Watchara Kasinrerk | en_US |
dc.contributor.author | Chatchai Tayapiwatana | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Chiang Mai University | en_US |
dc.date.accessioned | 2022-08-04T08:08:44Z | |
dc.date.available | 2022-08-04T08:08:44Z | |
dc.date.issued | 2021-06-01 | en_US |
dc.description.abstract | Adult-onset immunodeficiency syndrome (AOID) patients with autoantibodies (autoAbs) against interferon-gamma (IFN-γ) generally suffer from recurrent and recalcitrant disseminated non-tuberculous mycobacterial diseases. Since the early stages of AOID do not present specific symptoms, diagnosis and treatment of the condition are not practical. A simplified diagnostic method for differentiating AOID from other immunodeficiencies, such as HIV infection, was cre-ated. Anti-IFN-γ is generally identified using enzyme-linked immunosorbent assay (ELISA), which involves an instrument and a cumbersome process. Recombinant IFN-γ indirectly conjugated to colloidal gold was used in the modified immunochromatographic (IC) strips. The biotinylated-IFN-γ was incorporated with colloidal-gold-labeled 6HIS-maltose binding protein-monomeric streptav-idin (6HISMBP-mSA) and absorbed at the conjugate pad. The efficacy of the IC strip upon applying an anti-IFN-γ autoAb cut-off ELISA titer of 2500, the sensitivity and specificity were 84% and 90.24%, respectively. When a cut-off ELISA titer of 500 was applied, the sensitivity and specificity were 73.52% and 100%, respectively. | en_US |
dc.identifier.citation | Diagnostics. Vol.11, No.6 (2021) | en_US |
dc.identifier.doi | 10.3390/diagnostics11060987 | en_US |
dc.identifier.issn | 20754418 | en_US |
dc.identifier.other | 2-s2.0-85107827988 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/76156 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85107827988&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Latticed gold nanoparticle conjugation via monomeric streptavidin in lateral flow assay for detection of autoantibody to interferon-gamma | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85107827988&origin=inward | en_US |