Publication:
Validation of osteoporosis risk assessment tools in middle-aged Thai women

dc.contributor.authorS. Indhavivadhanaen_US
dc.contributor.authorM. Rattanachaiyanonten_US
dc.contributor.authorS. Angsuwathanaen_US
dc.contributor.authorK. Techatraisaken_US
dc.contributor.authorP. Tanmahasamuten_US
dc.contributor.authorP. Leerasirien_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-11T03:18:25Z
dc.date.accessioned2019-03-14T08:01:57Z
dc.date.available2018-12-11T03:18:25Z
dc.date.available2019-03-14T08:01:57Z
dc.date.issued2016-11-01en_US
dc.description.abstract© 2016 International Menopause Society. Objectives: To validate osteoporosis risk assessment tools in middle-aged Thai women. Methods: A total of 1038 women who had bone mineral density (BMD) measurements using dual-energy X-ray absorptiometry were reviewed. Clinical data were used to validate the diagnostic test performance of various osteoporosis risk assessment tools, including ABONE, FRAX®, ORAI, OSIRIS, SCORE, SOFSURF, and OSTA. The following parameters were evaluated: sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy; those with 95% confidence interval (CI) of the receiver operator characteristics area under the curve (ROC-AUC) > 0.5 were considered statistically significant. Results: The subjects had a mean age of 53.01 ± 6.20 years and body mass index (BMI) of 23.98 ± 3.38 kg/m2. Among the osteoporosis risk assessment tools being evaluated, the tools that had ROC-AUC >0.8 and 95% CI >0.5, and could predict osteoporosis at the femoral neck with high specificity of >75% and NPV of >90%, were FRAX® without BMD (ROC-AUC 0.83; 95% CI 0.73–0.93; specificity 99.90; NPV 98.89), SCORE (ROC-AUC 0.86; 95% CI 0.78–0.94; specificity 98.79; NPV 98.99), and OSTA (ROC-AUC 0.86; 95% CI 0.79–0.94; specificity 75.03; NPV 99.73). Conclusion: The prevalence of osteoporosis in the middle-aged Thai women attending Siriraj Menopause Clinic is 7.3% at the lumbar spine and/or femoral neck. FRAX® without BMD, SCORE, and OSTA have appropriate validity as tools for ruling out osteoporosis in these women.en_US
dc.identifier.citationClimacteric. Vol.19, No.6 (2016), 588-593en_US
dc.identifier.doi10.1080/13697137.2016.1231176en_US
dc.identifier.issn14730804en_US
dc.identifier.issn13697137en_US
dc.identifier.other2-s2.0-84988603394en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/41013
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988603394&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleValidation of osteoporosis risk assessment tools in middle-aged Thai womenen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988603394&origin=inwarden_US

Files

Collections