Publication: Boronic acid Functionalized Guided Mode Resonance Sensor for HbA1c Detection
dc.contributor.author | Boonrasri Seeleang | en_US |
dc.contributor.author | Songpol Ongwattanakul | en_US |
dc.contributor.author | Chamras Promptmas | en_US |
dc.contributor.author | Sakoolkan Boonruang | en_US |
dc.contributor.author | Waleed S. Mohammed | en_US |
dc.contributor.author | Romuald Jolivot | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Bangkok University | en_US |
dc.contributor.other | Thailand National Electronics and Computer Technology Center | en_US |
dc.date.accessioned | 2020-01-27T08:22:54Z | |
dc.date.available | 2020-01-27T08:22:54Z | |
dc.date.issued | 2019-01-10 | en_US |
dc.description.abstract | © 2018 IEEE. An alternative optical label-free sensor, Guided Mode Resonance (GMR), is demonstrated in this paper for detection of glycated hemoglobin (HbA1c). The GMR sensor surface is modified by cross-linking with 3-amino phenylboronic acids (3-APBA) using 3-(glycidyloxypropyl) trimethoxysilane (GOPTMS). 3-APBA provides a specific interaction with HbA1c under alkaline condition. The sensing scheme is performed by tracking a peak resonance in a reflection spectrum. That relies on changes in refractive index on the sensor's surface. Percent of HbA1c in total hemoglobin can be estimated using a ration of resonance shift due to absorbed HbA1c and the shift from changes in a bulk refractive index of a whole blood (Δλ HbA1c /Δλ TotalHb ). In the measurement, Lypochek diabetes controls having 5.1% (range: 4.6-5.6% measured by HPLC) and 9.5% (range: 8.5-10.4% measured by HPLC) HbA1c are used. The results from a resonance shift ration is linearly proportional to the measurement from the HPLC standard method with a precision of 7.71-20.77% CV. This guarantees boronate-modified GMR affinity sensor for the monitoring of glycemic status in diabetes management. | en_US |
dc.identifier.citation | BMEiCON 2018 - 11th Biomedical Engineering International Conference. (2019) | en_US |
dc.identifier.doi | 10.1109/BMEiCON.2018.8609979 | en_US |
dc.identifier.other | 2-s2.0-85062109854 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/50668 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062109854&origin=inward | en_US |
dc.subject | Computer Science | en_US |
dc.subject | Engineering | en_US |
dc.title | Boronic acid Functionalized Guided Mode Resonance Sensor for HbA1c Detection | en_US |
dc.type | Conference Paper | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062109854&origin=inward | en_US |