Publication:
Boronic acid Functionalized Guided Mode Resonance Sensor for HbA1c Detection

dc.contributor.authorBoonrasri Seeleangen_US
dc.contributor.authorSongpol Ongwattanakulen_US
dc.contributor.authorChamras Promptmasen_US
dc.contributor.authorSakoolkan Boonruangen_US
dc.contributor.authorWaleed S. Mohammeden_US
dc.contributor.authorRomuald Jolivoten_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherBangkok Universityen_US
dc.contributor.otherThailand National Electronics and Computer Technology Centeren_US
dc.date.accessioned2020-01-27T08:22:54Z
dc.date.available2020-01-27T08:22:54Z
dc.date.issued2019-01-10en_US
dc.description.abstract© 2018 IEEE. An alternative optical label-free sensor, Guided Mode Resonance (GMR), is demonstrated in this paper for detection of glycated hemoglobin (HbA1c). The GMR sensor surface is modified by cross-linking with 3-amino phenylboronic acids (3-APBA) using 3-(glycidyloxypropyl) trimethoxysilane (GOPTMS). 3-APBA provides a specific interaction with HbA1c under alkaline condition. The sensing scheme is performed by tracking a peak resonance in a reflection spectrum. That relies on changes in refractive index on the sensor's surface. Percent of HbA1c in total hemoglobin can be estimated using a ration of resonance shift due to absorbed HbA1c and the shift from changes in a bulk refractive index of a whole blood (Δλ HbA1c /Δλ TotalHb ). In the measurement, Lypochek diabetes controls having 5.1% (range: 4.6-5.6% measured by HPLC) and 9.5% (range: 8.5-10.4% measured by HPLC) HbA1c are used. The results from a resonance shift ration is linearly proportional to the measurement from the HPLC standard method with a precision of 7.71-20.77% CV. This guarantees boronate-modified GMR affinity sensor for the monitoring of glycemic status in diabetes management.en_US
dc.identifier.citationBMEiCON 2018 - 11th Biomedical Engineering International Conference. (2019)en_US
dc.identifier.doi10.1109/BMEiCON.2018.8609979en_US
dc.identifier.other2-s2.0-85062109854en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/50668
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062109854&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.titleBoronic acid Functionalized Guided Mode Resonance Sensor for HbA1c Detectionen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85062109854&origin=inwarden_US

Files

Collections