Publication: Immobilization-free electrochemical sensor coupled with a graphene-oxide-based aptasensor for glycated albumin detection
dc.contributor.author | Wassa Waiwinya | en_US |
dc.contributor.author | Thitirat Putnin | en_US |
dc.contributor.author | Dechnarong Pimalai | en_US |
dc.contributor.author | Wireeya Chawjiraphan | en_US |
dc.contributor.author | Nuankanya Sathirapongsasuti | en_US |
dc.contributor.author | Deanpen Japrung | en_US |
dc.contributor.other | Thailand National Nanotechnology Center | en_US |
dc.contributor.other | Faculty of Medicine Ramathibodi Hospital, Mahidol University | en_US |
dc.date.accessioned | 2022-08-04T08:11:20Z | |
dc.date.available | 2022-08-04T08:11:20Z | |
dc.date.issued | 2021-03-01 | en_US |
dc.description.abstract | An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels. | en_US |
dc.identifier.citation | Biosensors. Vol.11, No.3 (2021) | en_US |
dc.identifier.doi | 10.3390/bios11030085 | en_US |
dc.identifier.issn | 20796374 | en_US |
dc.identifier.other | 2-s2.0-85103919871 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/76256 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85103919871&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Immobilization-free electrochemical sensor coupled with a graphene-oxide-based aptasensor for glycated albumin detection | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85103919871&origin=inward | en_US |