Publication: Comparative accuracy of the InBios scrub typhus detect IgM rapid test for the detection of IgM antibodies by using conventional serology
dc.contributor.author | Hugh W.F. Kingston | en_US |
dc.contributor.author | Stuart D. Blacksell | en_US |
dc.contributor.author | Ampai Tanganuchitcharnchai | en_US |
dc.contributor.author | Achara Laongnualpanich | en_US |
dc.contributor.author | Buddha Basnyat | en_US |
dc.contributor.author | Nicholas P.J. Day | en_US |
dc.contributor.author | Daniel H. Paris | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Menzies School of Health Research | en_US |
dc.contributor.other | Churchill Hospital | en_US |
dc.contributor.other | Chiangrai Prachanukhru Hospital | en_US |
dc.contributor.other | Oxford University Clinical Research Unit | en_US |
dc.date.accessioned | 2018-11-23T09:38:13Z | |
dc.date.available | 2018-11-23T09:38:13Z | |
dc.date.issued | 2015-10-01 | en_US |
dc.description.abstract | Copyright © 2015, American Society for Microbiology. All Rights Reserved. This study investigated the comparative accuracy of a recombinant 56-kDa type-specific antigen-based rapid diagnostic test (RDT) for scrub typhus for the detection of IgM antibodies by using conventional serology in well-characterized serum samples from undifferentiated febrile illness patients. The RDT showed high specificity and promising comparative accuracy, with 82% sensitivity and 98% specificity for samples defined positive at an IgM indirect immunofluorescence assay positivity cutoff titer of ≥1:1,600 versus 92% and 95% at ≥1:6,400, respectively. | en_US |
dc.identifier.citation | Clinical and Vaccine Immunology. Vol.22, No.10 (2015), 1130-1132 | en_US |
dc.identifier.doi | 10.1128/CVI.00390-15 | en_US |
dc.identifier.issn | 1556679X | en_US |
dc.identifier.issn | 15566811 | en_US |
dc.identifier.other | 2-s2.0-84943262734 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/35377 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84943262734&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Immunology and Microbiology | en_US |
dc.subject | Medicine | en_US |
dc.title | Comparative accuracy of the InBios scrub typhus detect IgM rapid test for the detection of IgM antibodies by using conventional serology | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84943262734&origin=inward | en_US |