Publication:
Capillary blood beta-hydroxybutyrate measurement by reagent strip in diagnosing diabetic ketoacidosis.

dc.contributor.authorPuntip Tantiwongen_US
dc.contributor.authorGobchai Puavilaien_US
dc.contributor.authorBoonsong Ongphiphadhanakulen_US
dc.contributor.authorPongamorn Bunnagen_US
dc.contributor.authorChardpraorn Ngarmukosen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-06-21T08:09:08Z
dc.date.available2018-06-21T08:09:08Z
dc.date.issued2005-06-01en_US
dc.description.abstractOBJECTIVE: To compare blood beta-hydroxybutyrate (beta-OHB) levels measured by reagent strip with serum ketone levels assessed by the nitroprusside reaction in diagnosing diabetic ketoacidosis (DKA). DESIGN: Prospective study of DKA in 19 Thai diabetic patients from September 2001 until August 2002. SETTING: A university hospital. PATIENTS: Nineteen patients with DKA and ten patients with metabolic acidosis from other causes. INTERVENTIONS: Capillary blood alpha-OHB was measured by a blood ketone meter (MediSense Optium). Concurrently, serum ketone was measured semiquantitatively by nitroprusside reaction (Ketostix, N-multistix, and Labstix). MAIN OUTCOME MEASURE: Sensitivity, specificity, and ROC curve of both methods in diagnosing DKA. RESULT: Mean age +/- SD of DKA patients was 45.6 +/- 16.95 years. Plasma glucose was 675.25 +/- 188.15 mg/dL, arterial blood pH 7.19 +/- 0.12, anion gap and serum bicarbonate 29.93 +/- 4.90 and 8 +/- 3.35 mmol/L. Serum ketone was moderately to markedly positive in most cases. Capillary beta-OHB ranged from 2.4 to >6 mmol/L. The sensitivity and specificity of serum ketone by nitroprusside reaction in diagnosing DKA were 95% and 100%. The sensitivity and specificity of capillary beta-OHB was 90% and 100% respectively. The areas under ROC curves of serum ketone and capillary beta-OHB were 0.975 and 0.950 (NS) respectively. CONCLUSION: Serum ketone and blood beta-OHB measurement are equally effective in diagnosing DKA among uncomplicated cases.en_US
dc.identifier.citationClinical laboratory science : journal of the American Society for Medical Technology. Vol.18, No.3 (2005), 139-144en_US
dc.identifier.issn0894959Xen_US
dc.identifier.other2-s2.0-24944457298en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/16335
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=24944457298&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleCapillary blood beta-hydroxybutyrate measurement by reagent strip in diagnosing diabetic ketoacidosis.en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=24944457298&origin=inwarden_US

Files

Collections