Publication: The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA
dc.contributor.author | Patcharee Jearanaikoon | en_US |
dc.contributor.author | Preeda Prakrankamanant | en_US |
dc.contributor.author | Chanvit Leelayuwat | en_US |
dc.contributor.author | Surasak Wanram | en_US |
dc.contributor.author | Temduang Limpaiboon | en_US |
dc.contributor.author | Chamras Promptmas | en_US |
dc.contributor.other | Khon Kaen University | en_US |
dc.contributor.other | Ubon Rajathanee University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-12-11T03:04:20Z | |
dc.date.accessioned | 2019-03-14T08:01:44Z | |
dc.date.available | 2018-12-11T03:04:20Z | |
dc.date.available | 2019-03-14T08:01:44Z | |
dc.date.issued | 2016-03-01 | en_US |
dc.description.abstract | © 2015 Elsevier B.V. We have previously developed quartz crystal microbalance biosensor integrated with loop-mediated isothermal amplification (LAMP-QCM) for human papillomavirus (HPV) type58 DNA detection. Infection with HPV, particularly HPV16, remains a serious health problem due to its major risk factor contributing to cervical cancer. In the present study, LAMP-QCM biosensor was evaluated in terms of a quantitative assay for copy number of HPV16 DNA in cervical samples compared to quantitative PCR using TaqMan assay (TaqMan-qPCR). The detection limit of LAMP-QCM was found to be 10 fold more sensitive than TaqMan-qPCR with 100% specificity and 7.6% imprecision. Different plot of HPV16 DNA copy number using Bland-Altman analysis revealed 94% correlation between LAMP-QCM and qPCR. We therefore concluded that the developed LAMP-QCM biosensor provides a possible rapid and sensitive assay for HPV16 DNA quantification in a routine laboratory. | en_US |
dc.identifier.citation | Journal of Virological Methods. Vol.229, (2016), 8-11 | en_US |
dc.identifier.doi | 10.1016/j.jviromet.2015.12.005 | en_US |
dc.identifier.issn | 18790984 | en_US |
dc.identifier.issn | 01660934 | en_US |
dc.identifier.other | 2-s2.0-84960887737 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/40824 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84960887737&origin=inward | en_US |
dc.subject | Immunology and Microbiology | en_US |
dc.title | The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84960887737&origin=inward | en_US |