Publication:
Performance evaluation of the automated nucleated red blood cell enumeration on Sysmex XN analyser

dc.contributor.authorC. Tantanateen_US
dc.contributor.authorC. Klinbuaen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-23T09:42:08Z
dc.date.available2018-11-23T09:42:08Z
dc.date.issued2015-06-01en_US
dc.description.abstract© 2014 John Wiley & Sons Ltd. Introduction: Presence of peripheral blood nucleated red blood cell (NRBC) is associated with pathological conditions and leads to the overestimation of white blood cell count in automated haematology analysers (HA). The authors evaluated NRBC enumeration by a new HA Sysmex XN (XN) to demonstrate the precision and comparability to manual count (MC) at the various NRBC values. Methods: Specimens with initially NRBC positive were included. For precision assessment, 8 levels of NRBCs were repeatedly analysed. For comparison study, 234 specimens were analysed by both XN and MC. Results: For precision study, the percentage of coefficient of variation ranged from 14% to 45.6% and 1.2% to 4.4% for MC and XN, respectively. For comparison study between XN and MC, NRBCs ranged from 0% to 612.5%. Regression analysis demonstrated an r2of 0.98. The mean bias of 14.1% with 95% limits of agreement between -48.76% and 76.95% was found. The NRBC counts from XN appeared to be more in accordance with MC when the NRBCs were lower than 200% with the concordance rate of 94.2%. Conclusion: The automated NRBC enumeration by XN was precise and could replace the traditional MC, especially for the specimens with NRBCs lower than 200%.en_US
dc.identifier.citationInternational Journal of Laboratory Hematology. Vol.37, No.3 (2015), 341-345en_US
dc.identifier.doi10.1111/ijlh.12291en_US
dc.identifier.issn1751553Xen_US
dc.identifier.issn17515521en_US
dc.identifier.other2-s2.0-84928400833en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/35443
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84928400833&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titlePerformance evaluation of the automated nucleated red blood cell enumeration on Sysmex XN analyseren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84928400833&origin=inwarden_US

Files

Collections