Publication:
Development of push-pull osmotic tablets using Chitosan-poly(acrylic acid) interpolymer complex as an osmopolymer

dc.contributor.authorWichan Ketjindaen_US
dc.contributor.authorNuttanan Sinchaipaniden_US
dc.contributor.authorPichet Limsuwanen_US
dc.contributor.authorHans Leuenbergeren_US
dc.contributor.authorAmpol Mitrevejen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKing Mongkuts University of Technology Thonburien_US
dc.contributor.otherInstitute for Innovation in Industrial Pharmacy, Baselen_US
dc.date.accessioned2018-05-03T07:57:22Z
dc.date.available2018-05-03T07:57:22Z
dc.date.issued2011-03-01en_US
dc.description.abstractThe objectives of this study were to prepare push-pull osmotic tablets (PPOT) of felodipine using an interpolymer complex of chitosan (CS) and poly(acrylic acid) (PAA) as an osmopolymer, and to study the mechanisms of drug release from these tablets. The interpolymer complexes were prepared with different weight ratios of CS to PAA. Preparation of PPOT involved the fabrication of bilayered tablets with the drug layer, containing felodipine, polyethylene oxide, and the polymeric expansion layer, containing the CS-PAA complex. The effects of polymer ratios, type of plasticizers, and compression forces on release characteristics were investigated. It was found that drug release from PPOT exhibited zero-order kinetics and could be prolonged up to 12 or 24 h depending on the plasticizer used. PPOT using dibutyl sebacate showed a longer lag time and slower drug release than that using polyethylene glycol 400. In the case of polyethylene glycol 400, an increase in the CS proportion resulted in an increase in the drug release rate. The compression force had no effect on drug release from PPOT. Drug release was controlled by two consecutive mechanisms: an osmotic pump effect resulting in the extrusion of the drug layer from the tablet and subsequent erosion and dissolution of the extruded drug layer in the dissolution medium. The mathematical model (zero-order) related to extrusion and erosion rates for describing the mechanism of drug release showed a good correlation between predicted and observed values. © 2010 American Association of Pharmaceutical Scientists.en_US
dc.identifier.citationAAPS PharmSciTech. Vol.12, No.1 (2011), 132-140en_US
dc.identifier.doi10.1208/s12249-010-9572-zen_US
dc.identifier.issn15309932en_US
dc.identifier.other2-s2.0-79954424462en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/11350
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79954424462&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleDevelopment of push-pull osmotic tablets using Chitosan-poly(acrylic acid) interpolymer complex as an osmopolymeren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79954424462&origin=inwarden_US

Files

Collections