Publication: Evaluation of HIV-1 viral load detection by modified a commercial real-time PCR reagent used for light cycler 1.2 instrument
| dc.contributor.author | Sumonmal Uttayamakul | en_US |
| dc.contributor.author | Sirirat Likanonsakul | en_US |
| dc.contributor.author | Ruengpung Sutthent | en_US |
| dc.contributor.author | Achara Chaovavanich | en_US |
| dc.contributor.other | Bamrasnaradura Infectious Disease Institute | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.date.accessioned | 2018-08-24T01:59:17Z | |
| dc.date.available | 2018-08-24T01:59:17Z | |
| dc.date.issued | 2007-11-01 | en_US |
| dc.description.abstract | Objective: Commercial TaqMan real-time PCR reagent was modified and applied on Light Cylcer 1.2 for quantifying HIV-1 RNA in plasma and compared with the reference method; COBAS AmpliPrep/COBAS Amplicor HIV-1 monitor test version 1.5. Material and Method: Three hundred and eight frozen and fresh plasma samples were used for evaluation. Sequential specimens were also tested for follow-up cases. Results: The correlation between HIV-1 RNA values obtained by reference and modified method with automated and manual sample preparation were significant with r = 0.916 and 0.908 (p < 0.001, p < 0.001) respectively with similar agreement log of mean bias (0.5 versus 0.48). High degree of correlation and agreement were observed between the assays in blind fresh plasma, r = 0.953 (p < 0.001) with 0.15 log difference in HIV-1 RNA level. Among follow-up samples, both methods gave 100% concordant results. Conclusion: This modified protocol provided evidence for using modified commercial real-time PCR reagent for HIV-1 RNA quantitative detection as a monitoring tool for HIV/AIDS patients in Thailand. | en_US |
| dc.identifier.citation | Journal of the Medical Association of Thailand. Vol.90, No.11 (2007), 2429-2436 | en_US |
| dc.identifier.issn | 01252208 | en_US |
| dc.identifier.issn | 01252208 | en_US |
| dc.identifier.other | 2-s2.0-37148999653 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/24696 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37148999653&origin=inward | en_US |
| dc.subject | Medicine | en_US |
| dc.title | Evaluation of HIV-1 viral load detection by modified a commercial real-time PCR reagent used for light cycler 1.2 instrument | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37148999653&origin=inward | en_US |
