Publication: NephroCheck® Quality Test
dc.contributor.author | Thummaporn Naorungroj | en_US |
dc.contributor.author | Ary Serpa Neto | en_US |
dc.contributor.author | Fumitaka Yanase | en_US |
dc.contributor.author | Intissar Bittar | en_US |
dc.contributor.author | Glenn M. Eastwood | en_US |
dc.contributor.author | Rinaldo Bellomo | en_US |
dc.contributor.other | Siriraj Hospital | en_US |
dc.contributor.other | University of Melbourne | en_US |
dc.contributor.other | Monash University | en_US |
dc.contributor.other | Hospital Israelita Albert Einstein | en_US |
dc.contributor.other | Austin Hospital | en_US |
dc.contributor.other | Amsterdam UMC - University of Amsterdam | en_US |
dc.date.accessioned | 2022-08-04T09:20:54Z | |
dc.date.available | 2022-08-04T09:20:54Z | |
dc.date.issued | 2021-07-01 | en_US |
dc.description.abstract | Background: The acute kidney injury (AKI) risk score helps detect moderate and severe AKI in the next 12-24 h. However, inappropriate urine collection may impact its results. Aim: The aim of this study was to evaluate the stability of NephroCheck® after urine storage at different temperatures. Methods: The urine sample was centrifuged and split into 3 tubes. One was tested as soon as possible by the laboratory. The other 2 samples were frozen at-20 and-80°C, and the NephroCheck® test was performed 8 weeks later. Results: The mean values of the AKI risk score were 1.19 ± 0.93, 1.15 ± 1.14, and 1.20 ± 1.11 (ng/mL)2/1,000 for fresh urine,-20, and-80°C, respectively (p = 0.70). Spearman's rank correlation for-20 and-80°C versus immediate processing was strong with a rho of 0.82 and 0.98, respectively. Conclusion: The AKI risk score was relatively stable. Urine could be collected without dry ice or liquid nitrogen and kept for up to 8 weeks with either-20 or-80°C freezing with stable NephroCheck® results. | en_US |
dc.identifier.citation | Blood Purification. Vol.50, No.4-5 (2021), 489-491 | en_US |
dc.identifier.doi | 10.1159/000511727 | en_US |
dc.identifier.issn | 14219735 | en_US |
dc.identifier.issn | 02535068 | en_US |
dc.identifier.other | 2-s2.0-85097814625 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/78113 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85097814625&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | NephroCheck® Quality Test | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85097814625&origin=inward | en_US |